Specifications

Startup and General Configuration Summary
General Configuration Command Set
SecureStack B2 Configuration Guide 2-21
2.1.10.5 set switch
Use this command to assign a switch ID, to set a switch’s priority for becoming the management
switch if the previous management switch fails, or to change the switch unit ID for a switch in the
stack.
set switch {unit [priority value | renumber newunit]}
Syntax Description
Command Defaults
None.
Command Mode
Read-Write.
Examples
This example shows how to assign priority 3 to switch 5:
This example shows how to renumber switch 5 to switch 7:
unit Specifies a unit number for the switch.
priority value Specifies a priority value for the unit. Valid values are 1-
15 with higher values assigning higher priority.
renumber newunit Specifies a new number for the unit.
NOTE: This number must be a previously
unassigned unit ID number.
B2(rw)->set switch 5 priority 3
B2(rw)->set switch 5 renumber 7