Specifications
Logging And Network Management Command Set
Configuring Node Aliases
SecureStack B2 Configuration Guide 10-45
10.2.5.2 set nodealias
Use this command to enable or disable a node alias agent on one or more ports. Upon packet
reception, node aliases are dynamically assigned to ports enabled with an alias agent, which is the
default setting on SecureStack B2 devices. Node aliases cannot be statically created, but can be
deleted using the clear node alias config command as described in Section 10.2.5.3
.
set nodealias {enable | disable} port-string
Syntax Description
Command Defaults
None.
Command Type
Switch command.
Command Mode
Read-Write.
Example
This example shows how to disable the node alias agent on fe.1.3
:
enable | disable Enables or disables a node alias agent.
port-string Specifies the port(s) on which to enable or disable a node
alias agent. For a detailed description of possible
port-string values, refer to Section 3.1.1.
B2(rw)->set nodealias disable ge.1.3