Specifications

set system temperature
SecureStack B2 Configuration Guide 3-17
switches..Executingthiscommandwillresettheswitch,sothesystempromptsyoutoconfirm
whetheryouwanttoproceed.
Syntax
set system enhancedbuffermode {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
Thisexampleshowshowtoenableenhancedbuffermode:
B2(su)->set system enhancedbuffermode enable
Changes in the enhanced buffer mode will require resetting this unit.
Are you sure you want to continue? (y/n)
set system temperature
Usethiscommandtosetthesystemhightemperaturethresholdlimitandthehightemperatu re
alertparameters,ontheplatformsthatsupportthisfeature.
Syntax
set system temperature {[syslog enable | disable] [trap enable | disable]
[overtemp-threshold value]}
Parameters
Defaults
Syslogalertsaredisabledbydefault.
Trapalertsaredisabledbydefault.
Overtempthresholdis100%bydefault.
Mode
Switchcommand,readwrite.
enable|disable Enablesordisablesenhancedbuffermode.
syslogenable|
disable
Enablesordisableslogginghightemperaturealertstothesystemlog
whenthesystemtransitionsintoanalarmstate.
trapenable|disable EnablesordisablessendinghightemperaturealertsbymeansofSNMP
trapswhenthesystemtransitionsintoanalarmstate.
overtempthreshold
value
Setsthethermal
thresholdasapercentageofthemaximumratedforthe
specificplatform.Valuecanrangefrom0to100%.