Installation guide

CUSTOMER RELEASE NOTES
10/17/07 P/N: 9038177-17 Subject to Change Without Notice Page: 8 of 21
F0615-O
Client and Session Parameters:
Parameter:
Supported Value:
Authenticated and associated clients per radio
100
Clients who are authenticated but not yet associated are
included in the total
Active clients per radio
50
Total number of active clients simultaneously sending or
receiving data
Active AAA sessions (clients trying to
establish active connections) per RAS switch
RBT-81x0: 600
RBT-82x0: 1800
RBT-8400: 2500
AAA users configured in local user database
RBT-81x0: 999
RBT-82x0: 999
RBT-8400: 999
FIRMWARE CHANGES AND ENHANCEMENTS:
Firmware Release 6.0.4.4:
Resolved an issue where a bit on the non-mesh supported Access Points could be randomly set, causing the
APs to reset several times.
Resolved an issue where an external antenna attached to the TRPZ-MP-422 Access Point was not transmitting
the configured power.
Resolved an issue for the RBT-8400 where system generated core crash files were truncated and unreadable.
Firmware Release 6.0.4.2:
Added support for the TRPZ-MP-620 Outdoor Access Point. Direct Path Forwarding (Local Switching), Mesh
Services, and Wireless Bridging are only supported on the TRPZ-MP-620 and TRPX-MP-422 Access Points.
The RBT-8400 image is smaller than previous releases due to a shared library format introduced in the 6.0
firmware. Statically linked executables, which called to individual library functions, were replaced with run-time
calls, reducing the total number of individual library routines to be opened, and reducing the overall size of the
firmware required to operate the network switch. This format also increases the amount of memory available for
data transfer and table maintenance.
Resolved the issue where the Static IP configuration and deployment for the AP4102 and AP3000 did not
remain persistent with the AP upon reboot.
Resolved the erroneous message error printed to the CLI when the RBT-8400 reboots with 5.0.12.2:
Bootloader upgrade 5.0.x to 5.0.x needed. (x could be any number)
cp: /boot0/bload: No space left on device
Resolved an issue where the TRPZ-MP-422 Access Point image does not load with the 6.0.x code.
Resolved an issue where the configured APs in a network plan would crash upon RBT firmware upgrade due to
a DNS update entry on the RBT switch.
Resolved an issue where the Radius CLASS attribute was not sent with stop packets.
Resolved an issue where the RBT switch spoofed a DNS reply with a 169.254.x.x if the DNS server took more
than 3 seconds to respond. Certain Linux and Vista users will drop this packet causing everything to fail
Resolved an issue where the configured APs would crash with various exception messages, including TLB data
miss and sigtrap.
Resolved an issue where an expired password could be used to log into the system.
Resolved an issue where the APs may reset if the traffic load to the RBT switch host IP address exceeds
200Mb/s.
Resolved an issue where the configured AP name is not shown in the SNMP trap.
Resolved an issue where IP addresses were transposed in MIB queries that returned IP address information.