Installation guide
Troubleshooting Steps
D-2 Troubleshooting
3. Ifyoucannotaccesstheon‐boardconfigurationprogramviaaserialportconnection:
a. BesureyouhavesettheterminalemulatorprogramtoVT100compatible,8databits,1
stopbit,noparityand9600bps.
b. Checkthatthenull‐modemserialcableconformstothepin‐outconnectionsprovided
in
Appendix C.
4. Ifyouforgotorlostthepassword:
Youcanresettheaccesspointbacktoitsdefaultconfigurationbypressingtheresetbuttonon
thebackpanelfor5secondsormore.Youwilllose
allofyourconfigurationsettings.Then,
usethedefaultusername“admin”withthepassword“password”toaccessthemanagement
interface.
5. Ifallotherrecoverymeasuresfail,andtheaccesspointisstillnotfunctioningproperly,take
anyofthesesteps:
a. Resettheaccesspointusingtheconsoleinterface,Webinterface,
orthroughapowerreset.
b. Resettheaccesspointtoitsdefaultconfigu rationbypressingtheresetbuttonontheback
panelfor5secondsormore.Youwilllose
allofyourconfigurationsettings.Then,use
thedefaultusername“admin”withthepassword“password”toaccessthemanagement
interface.