Specifications
Logging And Network Management Command Set
Configuring System Logging
10-16 Matrix DFE-Gold Series Configuration Guide
10.2.1.9 set logging application
Use this command to set the severity level of log messages and the server(s) to which messages will
be sent for one or all applications.
set logging application {[mnemonic | all]} [level level] [servers servers]
Syntax Description
mnemonic Specifies a case sensitive mnemonic abbreviation of an
application to be logged. This parameter will vary
depending on the number and types of applications
running on your system. To display a complete list, use the
show logging application command as described in
Section 10.2.1.8. Sample values and their corresponding
applications are listed in Table 10-3.
all Sets the logging severity level for all applications.
level level (Optional) Specifies the severity level at which the server
will log messages for applications. Valid values and
corresponding levels are:
1 - emergencies (system is unusable)
2 - alerts (immediate action required)
3 - critical conditions
4 - error conditions
5 - warning conditions
6 - notifications (significant conditions)
7 - informational messages
8 - debugging messages
servers servers (Optional) Specifies index number(s) of the Syslog
server(s) to which messages will be sent. Valid values are
1 - 8 and are set using the set logging server command
(Section 10.2.1.3).
NOTE: Mnemonic values are case sensitive and must be typed as they appear in