Installation guide
Using LANVIEW
4-4 Troubleshooting
Amber
and off
Alternating (67% on,
33% off). Indicates that a
shutdown process has
completed. This
indication will remain for
60 seconds before
automatically restarting.
While in this state, you have 60 seconds to
safely remove the DFE module from the
chassis.
RX
(Receive)
None No link. No activity. Port
enabled or disabled.
None.
Green Solid. Link present, port
enabled, no traffic is
being received by the
interface.
None.
Amber Flashing. Link present,
port enabled, traffic is
being received by the
interface.
None.
RX Red Blinking. Indicates
collisions. This
indication is only
supported on 10/100
ports.
Contact Enterasys Networks for technical
support.
TX
(Transmit)
None Port enabled, but no
activity.
If it is known that the port should be active
and is not, contact Enterasys Networks for
technical support.
Green Flashing. Indicates data
transmission activity.
Rate of flashing indicates
the data rate.
None.
Red Flashing. Fault or Error
(collision).
None, unless there is a high rate of activity.
In this case, check for network
configuration problems or a defective
device.
Table 4-1 LANVIEW LEDs (Continued)
LED Color State Recommended Action