User Guide

WAN Configuration
2-28 Local Management User’s Guide
10. Use the arrow keys to highlight T1 Line Buildout (LBO). Press the SPACE bar to select to 0
dB unless the service provider recommends another setting, then press ENTER.
11. Use the arrow keys to highlight the SAVE command, then press ENTER. The message “SAVE
DONE!” displays and Local Management saves the changes to memory. “REBOOT IN
PROGRESS......” displays and the host platform reboots. Re-entry to management is necessary
for any further configuration.
12. Proceed to the next section to continue the configuration.
Frame Relay Interface Configuration
Access the WAN Interface Configuration screen through the WAN Physical Configuration screen,
by using the arrow keys to highlight the WAN INT CONFIG command, then press ENTER.
Proceed with the following steps to configure the WAN Interface.
1. Set the Interface Number that is being used for the WAN connection by typing the same number
into the Interface Number field that was input into the timeslots in the WAN Physical
Configuration screen, then press ENTER (see the Note on page 2-27). For Frame Relay PtoP:
The interfaces are assigned when DLCIs are created (in this case a zero needs to be entered in
this field).
2. Use the arrow keys to highlight FR LMI. Press the SPACE bar to select ANSI_94, T1.617-D
or Q.933-A, then press ENTER.
3. Make any changes to the available settings as desired.
4. Use the arrow keys to highlight SAVE, then press ENTER. The message “SAVE DONE!”
displays and Local Management saves the changes to memory.
In FR PtoP, the DLCIs must be entered statically, as they will not come up dynamically as in
FR PtoMP.
NOTE
The choice NO LMI under FR LMI is a test mode only and should not be used in a
practical application.