7.
Electrical Hazard: Only qualified personnel should perform installation procedures. Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion. Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. Notice Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice.
REGULATORY COMPLIANCE INFORMATION FEDERAL COMMUNICATIONS COMMISSION (FCC) NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules.
ELECTROMAGNETIC COMPATIBILITY (EMC) This product complies with the following: 47 CFR Parts 2 and 15, CSA C108.8, 89/336/EEC, EN 55022, EN 61000‐3‐2, EN 61000‐3‐3, EN 55024, AS/NZS CISPR 22, VCCI V‐3. COMPATIBILIDAD ELECTROMÁGNETICA (EMC) Este producto de Enterasys cumple con lo siguiente: 47 CFR Partes 2 y 15, CSA C108.8, 89/336/EEC, EN 55022, EN 55024, EN 61000‐3‐2, EN 61000‐3‐3, AS/NZS CISPR 22, VCCI V‐3.
ѻક䇈ᯢк䰘ӊ Supplement to Product Instructions 䚼ӊৡ⿄ (Parts) 䞥ሲ䚼ӊ (Metal Parts) ⬉䏃ഫ (Circuit Modules) ⬉㓚ঞ⬉㓚㒘ӊ (Cables & Cable Assemblies) ล᭭㘮ড়⠽䚼ӊ (Plastic and Polymeric parts) ⬉䏃ᓔ݇ (Circuit Breakers) ƻ˖ 䪙 3E ᳝↦᳝ᆇ⠽䋼ܗ㋴ (Hazardous Substance) ⒈㘨㣃 ∲ 䬝 ݁Ӌ䫀 3%% +J &G &U h ƻ ƻ ƻ ƻ ƻ h ƻ ƻ ƻ ƻ ƻ h ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ƻ ⒈Ѡ㣃䝮 3%'( 㸼⼎䆹᳝↦᳝ᆇ⠽䋼䆹䚼ӊ᠔᳝ഛ䋼ᴤ᭭Ёⱘ䞣ഛ SJ/T 11363-2006 ᷛޚ㾘ᅮⱘ䰤䞣㽕∖ҹϟDŽ Indicates that the concentration of the hazardous substance
VCCI NOTICE This is a class A product based on the standard of the Voluntary Control Council for Interference by Information Technology Equipment (VCCI). If this equipment is used in a domestic environment, radio disturbance may arise. When such trouble occurs, the user may be required to take corrective actions. BSMI EMC STATEMENT — TAIWAN This is a class A product. In a domestic environment this product may cause radio interference in which case the user may be required to take adequate measures.
DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Enterasys Networks, Inc. Manufacturer’s Address: European Representative Address: 50 Minuteman Road Andover, MA 01810 USA Enterasys Networks, Ltd.
ENTERASYS NETWORKS, INC. FIRMWARE LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between the end user (“You”) and Enterasys Networks, Inc.
3. APPLICABLE LAW. This Agreement shall be interpreted and governed under the laws and in the state and federal courts of the Commonwealth of Massachusetts without regard to its conflicts of laws provisions. You accept the personal jurisdiction and venue of the Commonwealth of Massachusetts courts.
8. AUDIT RIGHTS. You hereby acknowledge that the intellectual property rights associated with the Program are of critical value to Enterasys and, accordingly, You hereby agree to maintain complete books, records and accounts showing (i) license fees due and paid, and (ii) the use, copying and deployment of the Program.
x
Contents About This Guide Who Should Use This Guide ............................................................................................................... xv How to Use This Guide ...................................................................................................................... xvi Related Documents ........................................................................................................................... xvi Conventions Used in This Guide .......................
Connecting AC and RPS-SYS Power ..............................................................................................3-15 AC Power ..................................................................................................................................3-15 SecureStack Redundant Power System ...................................................................................3-17 Stack Manager Selection ..........................................................................................
Figures 1-1 1-2 3-3 3-4 3-5 3-6 3-7 3-8 3-9 3-10 3-11 3-12 3-13 3-14 3-15 3-16 3-17 3-18 3-19 3-20 3-21 4-22 4-23 A-1 C3G124-24 Stackable Switch ................................................................................................1-2 C3G124-48 Stackable Switch ................................................................................................1-3 Mini-GBIC with MT-RJ Connector..........................................................................................
xiv
About This Guide This guide provides an overview, installation and troubleshooting instructions, and specifications for the Enterasys® SecureStack C3G124‐24 and C3G124‐48 stackable Gigabit Ethernet switches. For information about the Command Line Interface (CLI) set of commands used to configure and manage the switches, refer to the Enterasys Networks® SecureStack C3 Configuration Guide.
How to Use This Guide How to Use This Guide Read through this guide completely to familiarize yourself with its contents and gain an understanding of the features and capabilities of the stackable Gigabit Ethernet switches. A general knowledge of data communications networks is helpful when setting up the switches. This preface provides an overview of this guide and the SecureStack C3 manual set, a brief summary of each chapter and defines the conventions used throughout this guide.
Conventions Used in This Guide Conventions Used in This Guide The following conventions are used in this guide: Note: Calls the reader’s attention to any item of information that may be of special importance. Caution: Contains information essential to avoid damage to the equipment. Precaución: Contiene información esencial para prevenir dañar el equipo. Achtung: Verweißt auf wichtige Informationen zum Schutz gegen Beschädigungen.
Getting Help Getting Help For additional support related to the switches or this document, contact Enterasys Networks using one of the following methods: World Wide Web www.enterasys.com/services/support/ Phone 1-800-872-8440 (toll-free in U.S. and Canada) or 1-978-684-1000 For the Enterasys Networks Support toll-free number in your country: www.enterasys.com/services/support/contact/ Internet mail support@enterasys.com To expedite your message, type [SWITCHING] in the subject line.
1 Introduction This chapter introduces the C3G124‐24 and C3G124‐48 stackable switches. For information about... Refer to page... Overview 1-1 Connectivity 1-4 Management 1-4 Standards Compatibility 1-5 LANVIEW Diagnostic LEDs 1-5 Overview The C3G124‐24 and C3G124‐48 are stackable Gigabit Ethernet switches, which can be adapted and scaled to help meet your network needs. These switches provide a management platform and uplink to a network backbone for a stacked group of up to eight C3 switches.
Overview • SFP slots that provide you with the option of installing Small Form Pluggable (SFP) Mini‐GBICs for 1000BASE‐SX/LX fiber‐optic connections and 1000BASE‐T copper connections. • Rear panel connectors for high‐speed connections in a stack configuration • Rear panel Redundant Power Supply connector for connection to a SecureStack redundant power supply system (C2RPS‐SYS ) using the appropriate cable (C2RPS‐PSM). Caution: The C3G124-24 and C3G124-48 are not PoE-compliant devices.
Overview Figure 1-2 C3G124-48 Stackable Switch C3G124-48 AC LINE 100-240 VAC 50-60 Hz 1.
Connectivity Connectivity The switch connects to Ethernet networks or workstations via the fixed front panel RJ45 connectors and four uplink ports that support optional Mini‐GBICs. At the time of this printing, the Mini‐GBICs that are available from Enterasys and supported by C3 switches are described in Table 1‐1 below. These Mini‐GBICs meet or exceed the IEEE 802.3z‐1998 standard.
Standards Compatibility Switch Configuration Using CLI Commands The CLI commands enable you to perform more complete switch configuration management tasks. For CLI command set information and how to configure the module, refer to the SecureStack C3 Configuration Guide. Standards Compatibility The 1000BASE‐T ports are compliant with the following standards and operations: • IEEE 802.3 • IEEE 802.3u • IEEE 802.
LANVIEW Diagnostic LEDs 1-6 Introduction
2 Network Requirements Before installing the device, review the requirements and specifications in this chapter. For information about... Refer to page... 10BASE-T Network 2-1 100BASE-TX Network 2-2 1000BASE-FX Network 2-2 1000BASE-T Network 2-2 Note: The network installation must meet the requirements described in this chapter to ensure satisfactory performance of this equipment. Failure to do so will produce poor network performance.
100BASE-TX Network 100BASE-TX Network When connecting a 100BASE‐TX segment to one of the fixed ports (1 through 24 on C3G124‐24, 1 through 48 on C3G124‐48), use Category 5 UTP cabling. The switch at the other end of the twisted pair segment must meet IEEE 802.3‐2002 100BASE‐TX Fast Ethernet network requirements for the switches to operate at 100 Mbps.
3 Hardware Installation Electrical Hazard: Only qualified personnel should perform installation procedures. Riesgo Electrico: Solamente personal calificado debe realizar procedimientos de instalacion. Elektrischer Gefahrenhinweis: Installationen sollten nur durch ausgebildetes und qualifiziertes Personal vorgenommen werden. Important Notice Read the Release Notes shipped with the switch to check for any exceptions to the supported features and operation documented in this guide.
Considerations Prior to Installation Considerations Prior to Installation When installing the switch, note the following: • Before starting the installation procedure, notify the network administrator of the installation. • Follow the installation procedures in the order as presented in this guide. • Do not connect the switch to the network until you have established the correct IP address. Required Tools A Phillips screwdriver is required to install the switch into a rack.
Installing Optional Mini-GBICs Installing Optional Mini-GBICs This section describes how to install Mini‐GBICs in any of the SFP port slots (21 through 24 of C3G124‐24 or 45 through 48 of C3G124‐48). It is recommended that the options be installed first in a new installation. Warning: Fiber-optic Mini-GBICs use Class 1 lasers. Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard.
Installing Optional Mini-GBICs Installation To install a Mini‐GBIC that has an MT‐RJ connector, refer to Figure 3‐3, or for a Mini‐GBIC with an LC connector, refer to Figure 3‐4, and proceed as follows: 1. Hold the Mini‐GBIC with the top side positioned as shown, and the 7‐pin edge connector facing the port slot. 2. Align the Mini‐GBIC with the port slot. 3. Push the Mini‐GBIC into the port slot until the Mini‐GBIC “clicks” and locks into place.
Installing Optional Mini-GBICs Figure 3-4 Mini-GBIC with LC Connector 1 Mini-GBIC (MGBIC-LC01 or MGBIC-LC09) 2 Mini-GBIC, top side 3 7-pin edge connector (insertion side) 4 Port slot 5 Protective dust cover 6 Release tab Removing the Mini-GBIC Caution: Do NOT remove a Mini-GBIC from a slot without releasing the locking tab located under the front bottom end of the Mini-GBIC. This can damage the Mini-GBIC. The Mini-GBIC and its host switch are sensitive to static discharges.
Installing the Switch on a Flat Surface 2. Remove the cables connected to the Mini‐GBIC. 3. Locate the release tab under the front end of the Mini‐GBIC. For the type of Mini‐GBIC shown in Figure 3‐3, push in on the release tab as far as it will go to release the Mini‐GBIC from the port slot. For the type of Mini‐GBIC shown in Figure 3‐4, pull out on the release tab to release the Mini‐GBIC from the port slot. 4. Grasp the sides of the Mini‐GBIC and pull it straight out of the port slot.
Installing the Switch on a Flat Surface Figure 3-5 Chassis Bottom, Rubber Feet Placement Á À Â Â Â Â 1 Bottom of chassis as seen when chassis is 3 Rubber feet with adhesive backing resting on its back (four) 2 Locations to install the rubber feet (four locations) 4. Remove the protective strip from the back of one rubber foot and position it on a marked location and press firmly into place. Repeat this procedure to install the remaining three rubber feet in the other three locations. 5.
Installing the Switch on a Flat Surface Caution: To ensure proper ventilation and prevent overheating, leave a minimum clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the switch. Do not connect the switch to the AC power source until instructed to do so later in the installation process. Precaución: Para asegurar una buena ventilación y evitar que el sistema se sobrecaliente, deje un espacio mínimo de 5.1 cm (2 pulgadas) con respecto a los lados y a la parte posterior del aparato.
Rack Mounting the Switch Rack Mounting the Switch To install the switch in a 19‐inch rack, you need: • Two rackmount brackets and mounting screws (rackmount kit) shipped with the switch. • Four user‐supplied screws to attach the switch to a standard 19‐inch rack. Guidelines for Rackmount Installation The installation site must be within reach of the network cabling and meet the requirements listed below: • Appropriate grounded power receptacles must be located within 152 cm (5 ft) of the location.
Rack Mounting the Switch Attaching Brackets and Installing in Rack Proceed as follows to install the switch into a 19‐inch rack: 1. Attach the rackmount brackets to the switch, as shown in Figure 3‐7, using the eight M3x6 mm flathead screws shipped with the switch. Figure 3-7 Attaching the Rackmount Brackets 1 Rackmount brackets 2. With the mounting brackets attached, position the switch between the vertical frame members of the 19‐inch rack as shown in Figure 3‐8.
Connecting High-Speed Stacking Cables Connecting High-Speed Stacking Cables The stack of switches can be connected in a ring or daisy chain topology. In a ring topology all the switches are connected. The only difference in the cable connections in a daisy chain topology is that one cable is not installed. Up to seven or eight switches can be stacked together and connected by high‐speed stacking cables. You can add switches and reach up to a maximum of 384 Ethernet ports per stack.
Configuring Switches in a Stack Figure 3-9 High-Speed Stacking Cable Connections Redundant Power Supply STACK UP AC LINE 100-240 VAC 50-60 Hz 0.8 A MAX STACK DOWN MAC ADDRESS Â À Â SERIAL NO. Ã Redundant Power Supply STACK UP AC LINE 100-240 VAC 50-60 Hz 0.8 A MAX STACK DOWN MAC ADDRESS Â À Â Á SERIAL NO. À Redundant Power Supply STACK UP AC LINE 100-240 VAC 50-60 Hz 0.8 A MAX STACK DOWN MAC ADDRESS Â À Â SERIAL NO.
Configuring Switches in a Stack Once installed in a stack, the switches behave and perform as a single switch. As such, you can start with a single switch and add more switches as your network expands. You can also mix different products in the family in a single stack to provide a desired combination of port types and functions to match the requirements of individual applications. In all cases, a stack of switches performs as one large product, and is managed as a single network entity.
Configuring Switches in a Stack Recommended Procedures for New and Existing Stacks Important The following procedures assume that all switches have a clean configuration from manufacturing. When adding a new switch to an already running stack, it is also assumed that the new switch is using the same firmware image version as other switches in the stack. Installing a New Stackable System of Up to Eight Switches Use the following procedure to install a new stack of up to eight switches out of the box.
Connecting AC and RPS-SYS Power Adding a New Switch to an Existing Stack Use the following procedure to install a new switch to an existing stack configuration. This procedure assumes that the new switch being added has a clean configuration from manufacturing and is running the same firmware image version as other switches in the stack. 1. Ensure that power is off on the new switch being installed. 2. Use one of the following methods to complete the stack cable connections: 3.
Connecting AC and RPS-SYS Power Figure 3-10 Switch Rear View ST AC K UP ST AC K DO WN AC 10 LIN 0-2 50 40 E 0.8 -60 VAC Hz A MA X MAC ADD RES S SER IAL Re du NO. nd an t Po we r Su pp Á ly  À 1 AC power cord 3. 2 AC power connector 3 Connector for external redundant power supply Observe that the power CPU LED (not shown), located on the front panel.
Connecting AC and RPS-SYS Power SecureStack Redundant Power System If you are installing an optional redundant power system (C2RPS‐SYS), refer to the installation instructions supplied with the SecureStack RPS. The switch is connected to a C2RPS‐SYS using a C2RPS‐PSM cable. Caution: To prevent damaging the switch, DO NOT connect a Power over Ethernet-compliant Redundant Power System (C2RPS-POE) to the redundant power supply connector.
Connecting to Console Port for Local Management Connecting to Console Port for Local Management This section describes how to install an RS232 DTE interface cable to a PC, a VT series terminal, or a modem to a SecureStack C3G124‐24 or C3G124‐48 for out‐of‐band sessions using CLI commands.
Connecting to Console Port for Local Management Figure 3-11 DB9 Male Console Port Pinout Assignments  5 Á À 1 9 1 2 3 Pin 2, Received Data (input) Pin 3, Transmitted Data (output) Pin 5, Signal Ground All other pins not connected. 6 Connecting to an IBM or Compatible Device To connect an IBM PC or compatible device, running the VT terminal emulation, to an Enterasys switch Console port (Figure 3‐12), proceed as follows: 1.
Connecting to Console Port for Local Management Figure 3-12 Connecting an IBM PC or Compatible Co ns ole MG RP CP Ä Ã 1 DB9 female connector 2 Serial interface cable 3 DB9 male Console port connector Á À U R S UP DO WN Â 4 DB9 female connector 5 PC with VT emulation application Connecting to a VT Series Terminal To connect a VT Series terminal to an Enterasys switch Console port (Figure 3‐13), use a UTP serial interface cable terminated with a DB9 female connector and a DB25 female connect
Connecting to Console Port for Local Management Figure 3-13 Connecting a VT Series Terminal Co ns ole MG R RP CP Ä Ã 1 DB9 female connector 2 Serial interface cable 3 DB9 male Console port connector Á À U S UP DO WN Â 4 DB25 female connector 5 PC with VT emulation application Connecting to a Modem To connect a modem to an Enterasys Networks switch modem port (Figure 3‐14), use a UTP cable terminated with a DB9 female connector and a DB25 male connector, and proceed as follows: 1.
Connecting to the Network Figure 3-14 Connecting to a Modem Co ns ole MG RP CP Æ Å Ä Ã 1 DB9 female cable connector 2 Serial interface cable 4 DB25 male connector 5 Local modem 3 DB9 male Console port 6 Remote modem Á À U R S UP DO WN Â 7 PC with VT emulation application Connecting to the Network The following procedures cover the cable connections from the network or other devices to the switch RJ45 ports or any installed optional Mini‐GBIC.
Connecting to the Network 2. Connect the twisted pair segment to the switch by inserting the RJ45 connector on the twisted pair segment into the desired RJ45 port (for example, Port 8). Figure 3-15 Connecting a UTP Cable Segment to RJ45 Port  1 1 2 3 4 5 6 7 8 9 2 10 11 12 À Á 11 12 1 RJ45 connector 2 Port 8 3. 3 Port 8 Link/Activity LED Verify that a link exists by checking that the Link/Activity LED is ON (solid green or blinking green).
Connecting to the Network Repeat all steps above until all connections have been made. Figure 3-16 Four-Wire Crossover Cable RJ45 Pinouts for 10/100BASE-TX À Á RX+ 1 1 RX+ RX 2 2 RX TX+ 3 3 TX+ TX 6 6 TX Ã Â 1 RJ45 switch port 2 Other device port Figure 3-17 3 RJ45-to-RJ45 crossover cable 4 RX+/RX- and TX+/TX-connections These connections must share a common color pair.
Connecting to the Network Figure 3-18 Eight-Wire Crossover Cable RJ45 Pinouts for 10/100/1000BASE-TX À Á TX1+ 1 1 TX2+ RX1- 2 2 RX2- TX2+ 3 3 TX1+ TX3+ 4 4 TX4+ RX3- 5 5 RX4- RX2- 6 6 RX1- TX4+ 7 7 TX3+ RX4- 8 8 RX3- Â 1 RJ45 device port 2 Other device port 3 RJ45-to-RJ45 crossover cable Figure 3-19 Eight-Wire Straight-Through Cable RJ45 Pinouts for 10/100/ 1000BASE-TX À Á TX1+ 1 1 TX2+ RX1- 2 2 RX2- TX2+ 3 3 TX1+ TX3+ 4 4 TX4+ RX3- 5 5 RX4- RX2-
Connecting to the Network Connecting Fiber-Optic Cables to MT-RJ Ports Warning: Fiber-optic Mini-GBICs use Class 1 lasers. Do not use optical instruments to view the laser output. The use of optical instruments to view laser output increases eye hazard. When viewing the output optical port, power must be removed from the network adapter. Advertencia: Los Mini-GBICS de fibra optica usan lasers de clase 1. No se debe usar instrumentos opticos para ver la potencia laser.
Connecting to the Network . Caution: Do not touch the ends of the fiber-optic strands, and do not let the ends come in contact with dust, dirt, or other contaminants. Contamination of cable ends causes problems in data transmissions. If the ends of the fiber-optic strands become contaminated, use a canned duster to blow the surfaces clean. A fiber-port cleaning swab saturated with optical-grade isopropyl alcohol may also be used to clean the ends.
Connecting to the Network 4. Verify that a link exists by checking that the port Link/Activity LED is on (blinking green or solid green). If the Link/Activity LED is off, perform the following steps until it is on: a. Verify that the device at the other end of the segment is ON and connected to the segment. b. If there are separate fiber‐optic connections on the other device, check the crossover of the cables. Swap the cable connections if necessary. c.
Connecting to the Network The transmit strand from a switch port connects to the receive port of a fiber‐optic Gigabit Ethernet device at the other end of the segment. The receive strand of the applicable LC port connects to the transmit port of the fiber‐optic Gigabit Ethernet device. Enterasys recommends labeling fiber‐optic cables to indicate receive and transmit ends. Many cables are pre‐labeled, providing matching labels or tapes at both ends of each strand of cable.
Connecting to the Network Figure 3-21 Cable Connection to LC Fiber-Optic Connectors 1 Mini-GBIC MT-RJ port connector 2 LC cable connector 3 Release tab 4 Link/Activity LED 3. Plug the other end of the cable into the appropriate port on the other device. Some cables may be terminated at the other end with two separate connectors, one for each fiber‐optic strand.
Completing the Installation Completing the Installation After installing the switch and making the connections to the network, access the switch management, as described below. Initial Logon to Switch Management To initially access switch management from your local PC, terminal, or modem connection, proceed as follows at the displayed startup screen: 1. Enter rw (Read‐Write) for Username. 2. At the Password prompt, press Enter (RETURN). 3.
Completing the Installation 3-32 Hardware Installation
4 Troubleshooting This chapter provides information concerning the following: For information about... Refer to page... Using LANVIEW 4-2 Troubleshooting Checklist 4-5 Using the Reset Switch 4-7 This device contains a battery that is not considered a user replaceable part. If the battery needs to be replaced, contact customer service for repair. Caution: There is a risk of explosion if the battery is replaced with an incorrect type. A used battery may be safely disposed in a municipal waste stream.
Using LANVIEW Using LANVIEW These switches support the Enterasys Networks built‐in LANVIEW LED visual diagnostic and status monitoring system. The LANVIEW LEDs on both the C3G124‐24 and C3G124‐48 are located in similar locations as shown on C3G124‐24 in Figure 4‐22. These LEDs allow you to quickly observe network status for diagnosing switch and network problems.
Using LANVIEW Table 4-3 LANVIEW LEDs LED Color State Recommended Action CPU Off Power disconnected. If the LED remains off after connecting AC power or DC power from an RPS, check the following: 1. Make sure there is power at the power source (AC source and RPS if applicable). 2. Replace the power cord with a known good one or check the continuity of the power cord. 3. If the switch still does not power up, the system may have a fatal error. Contact Enterasys Networks for technical support.
Using LANVIEW Table 4-3 LANVIEW LEDs (continued) LED Color State Recommended Action UP Off No valid connection to switch stack down connector. 1. Make sure the switch connected to the stack down connector is powered on. 2. Replace cable with a known good one. 3. If the problem still exists, contact Enterasys Networks for technical support. Green Solid. Valid connection to switch stack down connector. None. Blinking. Information is being transferred via the high-speed stacking cable.
Troubleshooting Checklist Table 4-3 LANVIEW LEDs (continued) LED Color State Recommended Action Link/ Activity Off 1. No link. None. 2. No activity or port in standby. None. 3. If the port is one of the highest numbered last four RJ45 ports, the port is deactivated because the Mini-GBIC port with the same port number is linked. None. 4. If the port is a Mini-GBIC port, the port is deactivated because the RJ45 port with the same port number is linked. None. Solid.
Troubleshooting Checklist Table 4-4 Troubleshooting Checklist (continued) Problem Possible Cause Recommended Action Cannot contact the switch through inband management. IP address not assigned. Refer to the SecureStack C3 Configuration Guide for the IP address assignment procedure. Port is disabled. This is normal if the switch is a Member in a stack. If operating as a standalone switch or as the Manager in a stack, enable the port.
Using the Reset Switch Using the Reset Switch If you forget the switch login password, use the Reset switch to reset the login password to the default password, as described in the following procedure. Figure 4-23 Reset Switch ST AC K UP ST AC K DO WN À 1 Reset switch To reset the switch password, refer to Figure 4‐23 and proceed as follows: Note: Notify the system manager before changing the password. 1. Press‐and‐hold the Reset switch while the switch is operational.
Using the Reset Switch 4-8 Troubleshooting
A Specifications This appendix provides information about the following: For information about... Refer to page... Switch Specifications A-1 Mini-GBIC Input/Output Specifications A-3 Gigabit Ethernet Specifications A-4 Console Port Pinout Assignments A-7 Regulatory Compliance A-7 Enterasys Networks reserves the right to change the specifications at any time without notice.
Switch Specifications Table A-1 C3G124-24 and C3G124-48 Specifications (continued) Item Specification C3G124-48 RJ45 ports 1 through 48 Forty-eight, 10BASE-T/100BASE-TX/1000BASE-T compliant ports with auto-sensing and auto-negotiation through the RJ45 connections. SFP ports 45 through 48 Four slots that support optional Mini-GBICs for 1000BASE-FX fiber-optic connections and 1000BASE-T copper connections.
Mini-GBIC Input/Output Specifications Table A-1 C3G124-24 and C3G124-48 Specifications (continued) Item Specification Predicted hours for Mean Time Between Failures (MTBF) Calculated following Bellcore TR-331 Issue 6 standard, at room temperature of 25°C.
Gigabit Ethernet Specifications Gigabit Ethernet Specifications The following specifications for the Mini‐GBICs shown in Table A‐3 through Table A‐10 meet or exceed the IEEE 802.3z‐1998 standard. MGBIC-LC01/MGBIC-MT01 Specifications (1000BASE-SX) Table A-3 MGBIC-LC01/MGBIC-MT01 Optical Specifications Item 62.5 µm MMF 50 µm MMF Transmit Power (minimum) -9.5 dBm -9.5 dBm Receive Sensitivity -17 dBm -17 dBm Link Power Budget 7.5 dBm 7.
Gigabit Ethernet Specifications Table A-6 MGBIC-LC03 Operating Range Item Modal Bandwidth @ 1310 nm Range 62.5 µm MMF 160 MHz/km 2,000 Meters 50 µm MMF 400 MHz/km 2,000 Meters MGBIC-LC09 Specifications (1000BASE-LX) Table A-7 MGBIC-LC09 Optical Specifications Item 62.5 µm MMF 50 µm MMF 10 µm SMF Transmit Power (minimum) -11.5 dBm -11.5 dBm -9.5 dBm Receive Sensitivity -20 dBm -20 dBm -20 dBm Link Power Budget 8.5 dBm 8.5 dBm 10.
Gigabit Ethernet Specifications Table A-10 MGBIC-08 Operating Range Item 1550 nm Range 9 or 10 µm SMF N/A 70,000 Meters MGBIC-02 Specifications (1000BASE-T) Table A-11 MGBIC-02 Specifications Item Specification Supported Cable: Type Copper, Category 5 UTP Maximum Length Up to 100 meters Connector RJ45 Data Rate 1 Gbps, IEEE 802.
Console Port Pinout Assignments Console Port Pinout Assignments The Console port is a DB9 serial communications port for local access to Local Management. Refer to Figure A‐1 for the Console port pin assignments. Figure A-1 Console Port Pinout Assignments  5 Á À 1 2 1 9 6 Pin 2, Received Data (input) Pin 3, Transmitted Data (output) 3 Pin 5, Signal Ground All other pins not connected.
Regulatory Compliance A-8 Specifications
Index Numerics H 1000BASE-SX/LX network connections requirements for 2-2 1000BASE-T requirements for 2-2 100BASE-TX requirements 2-2 10BASE-T connection 3-22 requirements 2-1 High-speed stack connections introduction to 1-3 High-speed stacking cables installation of 3-11 A AC input specifications A-2 C C3G124-24 overview of 1-1 C3G124-48 overview of 1-1 Cable Fiber budget A-3 Cable specifications 1000BASE-SX/LX network 2-2 1000BASE-T network 2-2 100BASE-TX network 2-2 10BASE-T network 2-1 CLI command i
UTP 4-wire crossover cable 3-24 UTP 4-wire straight-through cable 3-24 UTP 8-wire crossover cable 3-25 UTP 8-wire straight-through cable 3-25 Power connection AC 3-15 RPS DC 3-17 R Rackmount installation guidelines for 3-9 Receive/Transmit LEDs viewing of 4-2 Redundant Power Supply capability introduction to 1-3 Regulatory Compliance A-7 Regulatory compliance A-7 Related manuals xvi Reset switch 4-7 S Safety requirements A-7 Specifications A-1 C3G124-24 A-1 C3G124-48 A-2 MGBIC-08 A-5 MGBIC-LC01 A-4 MGBIC-