Specifications

set port inlinepower
SecureStack C3 Configuration Guide 3-37
C3(su)->show port inlinepower fe.1.1-6
Port Admin Oper Priority Class
------- ----- ---------------- -------- -----
fe.1.1 auto searching low 0
fe.1.2 auto searching low 0
fe.1.3 auto searching low 0
fe.1.4 auto searching low 0
fe.1.5 auto searching low 0
fe.1.6 auto searching low 0
set port inlinepower
UsethiscommandtoconfigurePoEparametersononeormoreports.
Syntax
set port inlinepower port-string {[admin {off | auto}] [priority {critical | high
| low}] [type type]}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtoenablePoEonportfe.3.1withcritical priority:
C3(su)->set port inlinepower fe.3.1 admin auto priority critical
portstring Specifiestheport(s)onwhichtoconfigurePoE.
adminoff|auto SetsthePoEadministrativestatetooff(di sabled)orauto(on).
prioritycritical|
high|low
Setstheport(s)priorityforthePoEallocationalgorit h m tocritical
(highest),highorlow.
typetype Specifiesastringdescribingthetype
ofdeviceconnectedtoaport.