Specifications
set inlinepower trap
3-36 Basic Configuration
Example
ThisexampleshowshowtosetthePoEthresholdto50onunit1:
C3(su)->set inlinepower threshold 50 1
set inlinepower trap
UsethiscommandtoenableordisablethesendingofanSNMPtrapmessageforaunitwhenever
thestatusofitsportschanges,orwhenevertheunit’sPoEusagethresholdiscrossed.Theunit’s
PoEusagethresholdmust besetusingthesetinlinepowerthresholdcommandasdescribedon
page3‐35.
Syntax
set inlinepower trap {disable | enable} module-number
Parameters
Mode
Switchcommand,read‐write.
Example
ThisexampleshowshowtoenablePoEtrapmessagingonunit1:
C3(su)->set inlinepower trap enable 1
show port inlinepower
UsethiscommandtodisplayallportssupportingPoE.
Syntax
show port inlinepower [port-string]
Parameters
Defaults
Ifnotspecified,informationforallPoEportswillbedisplayed.
Mode
Switchcommand,read‐only.
Example
ThisexampleshowshowtodisplayPoEinformationforFastEthernetports1through6inunit1.
Inthiscase,theports’administrativestate,PoEpriorityandclasshavenotbeenchangedfrom
defaultvalues:
disable|enable DisablesorenablesPoEtrapmessaging.
module‐number Specifiestheunitonwhich
todisableorenabletrapmessaging.
port‐string (Optional)DisplaysinformationforspecificPoEport(s).