Specifications
show system hardware
SecureStack C3 Configuration Guide 3-13
Example
Thisexampleshowshowtodisplaysysteminformation:
C3(su)->show system
System contact:John Smith
System location:Bldg10 2nd floor East
System name:10-2-C3
Switch 1
--------
PS1-Status PS2-Status
---------- ----------
Ok Not Installed and/or Not Operating
Fan1-Status Fan2-Status
----------- -----------
Ok Ok
Uptime d,h:m:s Logout
-------------- -------
2,19:57:39 5 min
Table 3‐2providesanexplanationofthecommandoutput.
show system hardware
Usethiscommandtodisplaythesystem’shardwareconfiguration.
Syntax
show system hardware
Parameters
None.
Defaults
None.
Table 3-2 show system Output Details
Output What It Displays...
System contact Contact person for the system. Default of a blank string can be changed with the
set system contact command (“set system contact” on page 3-24).
System location Where the system is located. Default of a blank string can be changed with the
set system location command (“set system location” on page 3-24).
System name Name identifying the system. Default of a blank string can be changed with the
set system name command (“set system name” on page 3-22).
PS1 and PS2-Status Operational status for power supply 1 and, if installed, power supply 2.
Fan Status Operational status of the fan trays.
Uptime d,h:m:s System uptime.
Logout Time an idle console or Telnet CLI session will remain connected before timing
out. Default of 5 minutes can be changed with the set logout command (“set
logout” on page 3-26).