Specifications

set rmon alarm status
SecureStack C3 Configuration Guide 12-13
set rmon alarm status
UsethiscommandtoenableanRMONalarmentry.Analarmisanotificationthatastatistical
sampleofamonitoredvariablehascrossedaconfiguredthreshold.
Syntax
set rmon alarm status index enable
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Usage
AnRMONalarmentrycanbecreatedusingthiscommand,configuredusingthesetrmonalarm
propertiescommand(“setrmonalarmproperties”onpage 1211),thenenabledusingthis
command.AnRMONalarmentrycanbecreatedandconfiguredatthesametimebyspecifying
anunusedindexwiththe
setrmonalarmpropertiescommand.
Example
ThisexampleshowshowtoenableRMONalarmentry3:
C3(rw)->set rmon alarm status 3 enable
index Specifiesanindexnumberforthisentry.Maximumnumberorentriesis
50.Maximumvalueis65535.
enable Enablesthisalarmentry.