Specifications
set logging application
11-8 Logging and Network Management
set logging application
Usethiscommandtosettheseverityleveloflogmessagesforoneorallapplications.
Syntax
set logging application {[mnemonic | all]} [level level]
Parameters
Defaults
Iflevelisnotspecified,nonewillbeapplied.
mnemonic Specifiesacasesensitivemnemonicabbreviationofanapplicationtobe
logged.Thisparameterwillvarydependingonthenumberandtypesof
applicationsrunningonyoursystem.Todisplayacompletelist,usethe
showloggingapplicationcommandasdescribedin
“showlogging
application”onpage 11‐7.Samplemnemonicsandtheircorresponding
applicationsarelistedinTable 11‐3onpage 11‐8.
Note: Mnemonic values are case sensitive and must be typed as they appear in
Table 11-3.
all Setstheloggingseveritylevelforallapplications.
levellevel (Optional)Specifiestheseveritylevelatwhichtheserverwilllog
messagesforapplications.Validvaluesandcorrespondinglevelsare:
1—emergencies(systemisunusable)
2—alerts(immediateactionrequired)
3—criticalconditions
4—errorconditions
5—warningconditions
6—notifications(significantconditions)
7—informationalmessages
8—debuggingmessages
Table 11-3 Mnemonic Values for Logging Applications
Mnemonic Application
CLIWEB Command Line Interface and Webview management
SNMP Simple Network Management Protocol
STP Spanning Tree Protocol
Driver Hardware drivers
System Non-application items such as general chassis management
Stacking Stacking management
UPN User Personalized Networking
Router Router