Installation guide
Installing the Device
Hardware Installation 3-5
4. Grasp the sides of the Mini-GBIC and pull it straight out of the port slot .
If storing or shipping the Mini-GBIC, insert the dust protector into the Mini-GBIC to protect the
fiber ports.
3.4 INSTALLING THE DEVICE
For a tabletop or shelf installation, locate the device within seven feet of its power source and on an
unrestricted free surface area as shown in Figure 3-3. If an optional redundant power system is
going to be installed and connected to the D-type cable connector on the rear of the device, refer to
the installation guide shipped with the redundant power system.
Proceed to Section 3.4.3 for power connection instructions.
Figure 3-3 Clearance Required for Tabletop or Shelf Installation
CAUTION: To ensure proper ventilation and prevent overheating, leave a minimum
clearance space of 5.1 cm (2.0 in.) at the left, right, and rear of the device.
C
A = 15 cm (4 in.)
B = 57 cm (22.5 in.)
C = 53 cm (21 in.)
D = 213 cm (7 ft)
B