Specifications

Enterasys Wireless Controller Software CLI Reference Guide 3-19
rtt min/avg/max/mdev = 0.204/0.281/0.423/0.101 ms
Thefollowingexamplefirstusestheshowtopologyl3commandtoobtaininterfacenamesforuse
withpingassourceaddresses.Then,thefollowingcommandpingsanIPaddressusingtheIP
addressofinterfacename“esa1”(asdeterminedwiththetheshowtopologyl3command)asthe
sourceaddress.
EWC.enterasys.com# ping source-interface name esa1 192.168.4.37
PING 192.168.4.37 (192.168.4.37) from 10.0.1.1 : 56(84) bytes of data.
64 bytes from 192.168.4.37: icmp_seq=1 ttl=64 time=0.042 ms
64 bytes from 192.168.4.37: icmp_seq=2 ttl=64 time=0.037 ms
64 bytes from 192.168.4.37: icmp_seq=3 ttl=64 time=0.039 ms
--- 192.168.4.37 ping statistics ---
3 packets transmitted, 3 received, 0% packet loss, time 1999ms
rtt min/avg/max/mdev = 0.037/0.039/0.042/0.005 ms
3.15 radtest
UsetheradtestcommandtotesttheRADIUSserversconnectivityandconfiguration.
Syntax
radtest <vns_name> <username> <password> [tracing]
radtest <vns_name> <username> [tracing]
Parameters
Examples
ThefollowingexampleteststheradiusserveronCNL7CP
EWC.enterasys.com# radtest CNL-7-CP sales abc123 tracing
Sending Captive portal authentication request to Radius Server for user sales,
with password abc123, on vns_name CNL-7-CP.
EWC.enterasys.com# show topology l3
Name Mode L3:IP
1:Admin admin 192.168.4.37
2:esa0 physical 10.0.0.1
3:esa1 physical 10.0.1.1
4:Enterasys-37Topology b@ac 10.10.1.1
<vns_name> SpecifiestheVNSserver
<username> Specifiesausername
<password> Specifiesapassword
tracing Specifiesthattracingwillbeused