Specifications
Enterasys Wireless Controller Software CLI Reference Guide 4-35
Examples
ThefollowingexampledisablestheaggregateMSDU.
EWC.enterasys.com:ap:defaults:11n:radio2# no n_aggr_msdu
4.3.1.10.17 n_aggr_msdu_max
Usethen_aggr_msdu_maxcommandtospecifythemaximumlengthofanA‐MSDU.The
n_aggr_msdu_maxcommandisaccessiblefromtheap:defaults:11n:radio2contextoftheCLI.
Syntax
n_aggr_msdu_max <2290-4096>
Parameters
Examples
ThefollowingexamplesetsthemaximumlengthoftheaggregateMSDUto3000bytes.
EWC.enterasys.com:ap:defaults:11n:radio2# n_aggr_msdu_max 3000
4.3.1.10.18 n_chlbonding
Usethen_chlbondingcommandtospecifythechannelbondingtype—upordown.The
n_chlbondingcommandisaccessiblefromtheap:defaults:11n:radio2contextoftheCLI.
Syntax
n_chlbonding (up|down)
Parameters
Examples
Thefollowingexamplesetsthechannelbondingtypeasup.
EWC.enterasys.com:ap:defaults:11n:radio2# n_chlbonding up
<2290‐4096> ThemaximumsizeofbytesofaA‐MSDU.Therangeofvalues
allowedis2290to4096.
up Theprimarychannel(20MHz)isbondedwithanextension
channelthatis20MHzabove(bondingup)theprimarychannel.
down Theprimarychannel(20MHz)isbondedwithanextension
channelthatis20MHzbelow(bondingdown)theprimary
channel.
Note: Depending on the channel you have selected, you may be prevented from bonding up or
down. For more information, see the Enterasys Wireless Controller, Access Points and
Convergence Software User Guide.