Chapter 2 Network Management Tools
Managing the XSR
Using SNMP for Downloads
You can use an SNMP manager to download or upload firmware from a
remote server, and copy a configuration image file to the XSR. Only run-
time/online mode downloads are supported. This requires setting the
ctDLNetAddress and ctDLFileName objects and issuing a ctDLOnLineDownLoad
defined in the CTRON-DOWNLOAD-MIB. For more details refer to the
following URL: http://www.enterasys.com/support/mibs
Fault Report
A fault report can be uploaded through TFTP. The mechanism to upload the
crash report is the same as the one used to upload configuration file. Refer to
“Performing Fault Management” on page 26 for more information.
Auto-discovery
The NetSight Gateway Management Tool can auto-discover an XSR on the
network using SNMP with the following MIB variables:
SysDesr
SysObjID
Sysuptime
NetSight also performs auto-discovery via ping using ICMP ping.
Statistics
For SNMP support, SNMP gets are supported as listed in Table 5. Also, refer
to NetSight Atlas Router Services Manager v2.0 to query and change SNMP
values.
Alarm Management (Traps)
The following events are supported by SNMP traps: link up, link down, warm
start, cold start, authentication error, and Entity Trap Configuration Change.
SNMP alarms are listed in Appendix A: “System Alarms and Events” on
page 357.