User`s guide
XSR User’s Guide 363
Appendix A Alarms and Events
Alarms/Events and System Limits
T1E1 LOF alarm on receiver cleared. Indicates that T1/E1 physical port is not detecting OOF Alarm.
T1E1 Transmiting Remote Alarm (Yellow
Alarm).
Indicates that T1/E1 physical port is transmitting remote alarm.
T1E1 Transmit Remote Alarm cleared. Indicates that T1/E1 physical port is not transmitting remote alarm.
SYNC_
DRIV
The ISR could not be connected The driver failed to connect the ISR to the BSP, therefore it will not be
started
SYNC_
DRIV
Init string parse failure The driver could not parse the initialization string and therefore it will
not be started
SYNC_
DRIV
Unrecoverable error The device has an un-recoverable error
SYNC_
DRIV
OS initialization failure The operating system failed to initialize the driver properly, therefore
the device cannot be started.
SYNC_
DRIV
Device not found The device could not be found on the PCI bus, so the driver cannot be
started
SNMP Failed to enable SNMP server Failed to start SNMP server due to failed in the locking mechanism or
the message queue is full.
SNMP Failed to disable SNMP server Failed to start SNMP server due to failure in the locking mechanism.
PLATF System reset from <reason>,
<warm|cold> start
“Warm start, cold start with following reasons:
- default config init “”dcfg””
- crash reset ”crsh””
- cli reset “”cli “”
- SNMP reset ”snmp””
- bootrom reset ”btrm””
- software checksum invalid “”cksm””
PLATF Failed to initialize sysLog socket Cannot create socket for sending syslogs
PLATF Failed to bind to sysLog port 514 Cannot bind to port 514 for sending syslogs
ISDN <BRI c/p>, SPID <spid string>
Registered (CES <1|2)
Displayed when BRI with North American switch types registers with
the central office successfully
ISDN <BRI c/p>, Unsolicited
SME_TERM_REGISTER_ACK
Displayed when BRI with North American switch types registers with
the central office but fails
ISDN <BRI c/p>, Registration Failed, Cause
<number>
Displayed when BRI with North American switch types registers with
the central office and fails. Cause 100: SPID configuration error, 41:
Network timeout and 1: Fit timeout
Table 16 High Severity Alarms/Events (Continued)
Module Message Description