User`s guide
362 XSR User’s Guide
Alarms and Events Appendix A
Alarms/Events and System Limits
Alarms and Events
The XSR exhibits the following alarm logging behavior:
Refer to the table below for all High severity alarms and events reported by
the XSR. All of the following messages are USER_LEVEL facility except for
those in bold and red text which are SECURITY_LEVEL.
Table 15 Alarm Behavior
When alarm logging is set to: The XSR-1805 will log:
HIGH HIGH severity alarms only
MEDIUM MEDIUM and HIGH severity alarms
LOW LOW, MEDIUM, and HIGH severity alarms
DEBUG all alarms
Table 16 High Severity Alarms/Events
Module Message Description
WEB Failed to enable Web server HTTP server is not enabled properly - cannot accept client connection
WEB Failed to enable Web server HTTP server is not enabled properly - cannot listen to incoming
requests
WEB Failed to enable Web server HTTP server is not enabled properly - cannot set socket options
WEB Failed to enable Web server HTTP server is not enabled properly - cannot bind socket
WEB Failed to enable Web server HTTP server is not enabled properly - cannot listen to socket
Various
modules
Interface <interface name>, changed
state to up
An interface link comes up
Various
modules
Interface <interface name>, changed
state to down
An interface link goes down
T1E1 Receiver has Loss of Frame (Yellow
Alarm).
Indicates that T1/E1 physical port is detecting OOF Alarm.