Specifications

System Description
1-6 Overview
Rate enforcement (CIR) with automatic rate fallback via traffic/adaptive shaping when the
network is congested. Automatically restores normal rates when congestion removed
Congestion control: Backward and Forward Explicit Congestion Notification (BECN/FECN)
Standard LMIs: ILMI, ANSI Annex D, CCITT Annex A and:
Auto option for LMI detection/adaptation
None option for directly connecting XSRs
Periodic Keep-Alive messages to learn of connection problems
Multi-protocol interconnect over Frame Relay - RFC-2427
RFC-2390 Frame Relay Inverse ARP to discover IP address of remote peer when used in multi-
point mode and responds to incoming Inverse ARP requests independent of P2P or MP2P
Multiple logical interfaces over the same physical Frame Relay port: sub-interfaces
Quality of Service: standard FIFO queuing, or IP QoS on DLCIs.
Max PDU size of 1600 bytes
Traffic shaping
Frame Relay Fragmentation Implementation Agreement (FRF.12)
Data Communications Equipment (DCE) support
Frame Relay over ISDN
Remote Auto Install over Frame Relay
Dynamic Host Configuration Protocol (DHCP)
Temporary or permanent network (IP) address allocation to clients
Network configuration parameter assignment to clients
Persistent storage/database of network values for network clients - Bindings Database
Persistent storage of network client lease states kept across reboot
Persistent and user-controllable conflict avoidance to prevent duplicate IP address including
configurable ping checking
Visibility of DHCP network activity and leases through operator reports statistics and logs
•DHCP Client
Integrated Services Digital Network (ISDN) - BRI/PRI
Circuit Mode Data (CMD): Channels (DS0s) are switched by the CO to the destination user for
the duration of the call
Outgoing calls supported for Backup, DoD/BoD
Incoming calls routed to the correct protocol stack based on called number/sub-address and
calling number/sub-address
Permanent B-channel support, i.e. 64 or 128 kbps lease line. Each BRI port can be set for CMD
or Leased-Line mode of operation
BRI supported switches: ETSI