Specifications

SPECTRUM Software Release Notice (SSRN)
For SPECTRUM 6.6 with Service Pack 2 CD release
Page 62
Document 5135
SynOptics Modules
6 Attempts to change all Module Ring
Attachments and the Module Ring Speed
for all attachments in a Token Ring
Module Configuration view fail when
done simultaneously during the editing
session.
This is a firmware issue. Change the
Module Ring Attachments then change
the Module Ring Speed (or vice versa).
Do not try to change both at the same
time.
Management Module Information
MM Part Number Device(s) Firmware Version
SM-SYN1001 HubSyn3FDDI (SynOptics 3000) 5.1.0
SM-SYN1002 HubSynEnet28xx (SynOptics 28xx) 5.3.1
SM-SYN1004 SynOptics 332xS (Enet Bridge) 1.0.0
SM-SYN1005 SynOptics 39xx (FDDI) 2.0.48
SM-SYN1006 SynOptics 28xxx 2.0.3
SM-SYN1008 HubSyn27xx (SynOptics 27xx) 5.11
SM-SYN1009 HubSyn29xx (SynOptics 29xx) 2.2.4
Known Anomalies: SynOptics Modules
Item Description Solution
1 Inaccurate statistics can appear in the
SynOptics Port Performance view.
This is a firmware issue.
Known Anomalies: SynOptics 5000 Hubs
Item Description Solution