Specifications
SPECTRUM Software Release Notice (SSRN)
For SPECTRUM 6.6 with Service Pack 2 CD release
Page 40
Document 5135
Level I Developer’s Toolkit
SpectroGRAPH
Known Anomalies: Level I Developer’s Toolkit
Item Description Solution
1 When you run the MTE and import a MIB
with an object name longer than 30
characters, you receive the following
message, even when the object does not
import:
The MIB was successfully imported.
In a terminal window or on the Control
Panel, error messages display for MIB
objects with names consisting of 30 or
more characters that failed to import.
There are two workarounds:
1. The first is to identify each MIB
object with 30+ characters in its
name and shorten the name before
running the MTE.
2. The second (for attributes with
truncated group names) is to find
the attributes that are listed as no
group and manually assign the
truncated group name in the
Attribute View.
If the MTE was run from the Control
Panel, a list of MIB objects that did not
import display on the Control Panel.
If the MTE was run from the command
line, a list of MIB objects that did not
import display in that window.
This issue will be corrected in a future
release of SPECTRUM.
Known Anomalies: SpectroGRAPH
Item Description Solution
1 When running SpectroGRAPH on the
Windows platform, links between certain
models such a Rpt_Segment (Fanout)
model and a Pingable model, will display
green even though Live Pipes is not
enabled on the link. Also, in these
unusual cases, the link will stay green
even when the modeled link is down.
There is a flaw in SpectroGRAPH on the
Windows platform which will be
corrected in 6.6 Service Pack 3.