Specifications

Enterasys X-Pedition 8000/8600 Getting Started Guide 71
Installing the Hardware
Installing Line Cards
You can install line modules in slots 1 to 7 on the X-Pedition 8000 (slot 0 allows a control module
only) or 1 to 15 on the X-Pedition 8600 (again, slot 0 allows a control module only). If you plan to
install a redundant control module, you may install line cards in slots 2–7 on the X-Pedition 8000
and 2–15 on the X-Pedition 8600. Before you begin, please review Table 19 for system firmware
requirements, restrictions, and special instructions that apply to the line card you are installing.
ELECTRICAL HAZARD: Only qualified personnel should perform installation procedures.
Table 19. Line card installation notes
Minimum
Firmware
Restrictions Special Instructions
SSR-ARE
Note: The SSR-ARE is designed for the
X-Pedition 8000/8600 only—do not try to
install these modules in any other units. Do
not install the SSR-ARE in slot 0 or 1 on the
X-Pedition 8000 or slot 0, 1, or 15 on the
X-Pedition 8600.
SSR-ATM29-02 3.0.0.0
CLI Setup
Enter the following commands at the CLI before
implementing any configurations.
1. Enable —> Configuration —> <Enter>.
2. Once you reach the configuration prompt, you
can create the ATM interface using CLI
commands as described in the ATM section of
the X-Pedition CLI manual. Enter the ?
character to view the options available to you in
configuration mode.
Proper Boot sequence
The control module on the chassis should indicate
that the SSR-ATM29-02 was detected and is
operating correctly.
Common Errors
Make sure the chassis is connected to a terminal
through a console port.
Helpful CLI Commands for Debugging
System show hardware
System show version
System show bootlog