Specifications

Enterasys Xpedition 8000/8600 Getting Started Guide 55
Installing the Hardware
XP-8600 DC Power Supply
Figure 27 shows the front view of an XP-8600 DC power supply.
Figure 27. Front view of an XP-8600 DC power supply
The XP-8600 DC power supply has a five-terminal wiring block on the front panel. The
wiring block contains two positive (+) terminals, two negative (-) terminals, and a safety
ground. The DC supply is designed to be powered by a 48-volt DC source.
Internally, the XP-8600 DC power supply consists of two separate power supplies. Each of
these internal power supplies must be energized to produce sufficient power for the XP-
8600 to operate. Each internal power supply is connected to source power through a pair
of positive (+) and negative (-) wiring lugs on the wiring block. Figure 28 shows the
internal relationship of the wiring lugs of the XP-8600 DC power supply.
Note: For the XP-8600 to work properly, both positive (+) terminals and both negative
(-) terminals of the XP-8600 DC power supply MUST be connected to the DC
source.
PWR
G86-PDC
SN
48/60V
27A MAX
!
To be installed in a restricted
access area in accordance
with the NEC or authority
having jurisdiction.
See manual for installation
instructions.