Overview of DFE-Platinum Module Shutdown Procedure (Special Instructions)
Matrix DFE-Series Module Installation Guide 4-7
Recommended Shutdown Procedure Using OFFLINE/RESET
Switch
Before pulling a DFE-Platinum module out of a chassis,
press or tap on its OFFLINE/RESET switch for less than 1 second.
Its CPU LED changes from solid green to blinking between green and amber, indicating
that the module is shutting down. At the end of the shutdown routine, the CPU LED
changes to a 67%/33% sequence of amber/off, respectively, indicating the module is in a
halt state. In this time it is safe to restart or remove the module from the chassis.
When a controlled shutdown is initiated from the OFFLINE/RESET switch, you have 60
seconds from the time the CPU starts alternately flashing amber/off until the device
automatically restarts.