Datasheet

Using LANVIEW
4-2 Troubleshooting
To view the receive and transmit activity on a group of attached segments, press the
GROUP SELECT button (see Figure 4-1) to step to the group of interest (Groups 1 through
4). Each time the GROUP SELECT button is pressed, the GROUP LED lights up in
sequence, indicating which group is selected. The receive and transmit activity for that
group of segments is then indicated by the RX and TX LEDs for each port.
Table 4-3 describes the LED indications and provides recommended actions as
appropriate.
Figure 4-1 LANVIEW LEDs
1 MGMT LED 2 Group 1, Port 1 LEDs
Note: The terms flashing, blinking, solid, and Alternately used in Tab le 4 -3 indicate
the following:
Flashing indicates an LED is flashing randomly.
Blinking indicates an LED is flashing at a steady rate (approximately 50% on, 50% off).
Solid indicates a steady LED light. No pulsing.
Alternately indicates an LED is flashing at a steady rate other than 50% on, 50% off.
1X
G
R
O
U
P
1
11X
OFFLINE/
RESET
COM
CPU
MGMT
GROUP
SELECT
GROUP
1
2
1
2
3
4
5
6
7
8
9
10
11
12
7H4382-25
FAST ENET
GROUP
GROUP
SELECT
RX TX
À
Á