Installation guide
Using LANVIEW
Troubleshooting 4-3
Table 4-1 LANVIEW LEDs
LED Color State Recommended Action
CPU Off Power off. Ensure chassis has adequate power.
Red Blinking. Hardware
failure has occurred.
Contact Enterasys Networks for technical
support.
Solid. Resetting, normal
power up reset.
If the LED remains red for several minutes,
contact Enterasys Networks for technical
support.
Amber Blinking. Crippled. Contact Enterasys Networks for technical
support.
Solid. Testing. If the LED remains amber for more than
several minutes, contact Enterasys
Networks for technical support.
Green Solid. Functional. None.
Amber
and
Green
Booting. Blinks amber
and green while booting.
None.
RX
(Receive)
Off No link.
No activity or port in
standby. Port enabled or
disabled.
None.
Green Solid. Link, port enabled,
no activity.
None.
Blinking. Link, port
disabled.
None.
Amber Flashing. Link, port
enabled, activity.
None.
Red Solid. Diagnostic failure. Contact Enterasys Networks for assistance.