6H302-48 and 6H303-48 Fast Ethernet User’s Guide FAST ENET FAST ENET 6H303-48 6H302-48 1X RESET RESET COM COM CPU 12X GROUP SELECT G R O U P GROUP GROUP G R O U P 1 1 1X 11X 13X G R O U P 24X G R O U P 2 2 13X 23X 25X G R O U P 36X G R O U P 3 3 25X 35X 37X G R O U P 48X G R O U P 4 4 37X 47X 9033387-05 CPU GROUP SELECT GROUP GROUP
NOTICE Enterasys Networks reserves the right to make changes in specifications and other information contained in this document and its web site without prior notice. The reader should in all cases consult Enterasys Networks to determine whether any such changes have been made. The hardware, firmware, or software described in this document is subject to change without notice.
FCC NOTICE This device complies with Part 15 of the FCC rules. Operation is subject to the following two conditions: (1) this device may not cause harmful interference, and (2) this device must accept any interference received, including interference that may cause undesired operation. NOTE: This equipment has been tested and found to comply with the limits for a class A digital device, pursuant to Part 15 of the FCC rules.
ENTERASYS NETWORKS, INC. PROGRAM LICENSE AGREEMENT BEFORE OPENING OR UTILIZING THE ENCLOSED PRODUCT, CAREFULLY READ THIS LICENSE AGREEMENT. This document is an agreement (“Agreement”) between You, the end user, and Enterasys Networks, Inc. (“Enterasys”) that sets forth your rights and obligations with respect to the Enterasys software program (“Program”) in the package. The Program may be contained in firmware, chips or other media.
5. UNITED STATES GOVERNMENT RESTRICTED RIGHTS. The enclosed Product (i) was developed solely at private expense; (ii) contains “restricted computer software” submitted with restricted rights in accordance with section 52.227-19 (a) through (d) of the Commercial Computer Software-Restricted Rights Clause and its successors, and (iii) in all respects is proprietary data belonging to Enterasys and/or its suppliers.
DECLARATION OF CONFORMITY Application of Council Directive(s): 89/336/EEC 73/23/EEC Manufacturer’s Name: Manufacturer’s Address: European Representative Address: Conformance to Directive(s)/Product Standards: Equipment Type/Environment: Enterasys Networks, Inc. 35 Industrial Way PO Box 5005 Rochester, NH 03866-5005 Enterasys Networks Ltd.
Contents Figures ............................................................................................................................................ix Tables.............................................................................................................................................. x ABOUT THIS GUIDE Using This Guide.............................................................................................................xi Structure of This Guide ...............................
3 3.1 3.2 3.3 3.4 3.5 4 A B 3.6 Unpacking the Module .................................................................................... 3-2 Installing Optional FLASH Upgrade ................................................................ 3-2 Installing the Module into the Matrix E7 Chassis ............................................ 3-2 Installing the Module into the 6C105 Chassis ................................................. 3-5 Connecting to the Network.........................................
Figures Figure 1-1 3-1 3-2 3-3 3-4 3-5 3-6 4-1 4-2 B-1 B-2 B-3 Page 6H302-48 and 6H303-48 Modules .................................................................................. 1-2 Installing a Module into the Matrix E7 Chassis................................................................ 3-4 Installing a Module into the 6C105 Chassis .................................................................... 3-6 Connecting a Twisted Pair Segment to the 6H302-48 .............................................
Tables Table 3-1 4-1 4-2 A-1 A-2 A-3 x Page Contents of Module Carton ...........................................................................................3-2 LANVIEW LEDs ............................................................................................................4-3 Troubleshooting Checklist.............................................................................................4-5 6H302-48 / 6H303-48 Specifications ...............................................................
About This Guide Welcome to the 6H302-48 and 6H303-48 Fast Ethernet User’s Guide. This guide describes the Fast Ethernet modules and provides information concerning network requirements, installation, and troubleshooting. For information about how to use Local Management to configure and manage the module, refer to the Matrix E7 Series and SmartSwitch 6000 Series Local Management User’s Guide.
Structure of This Guide STRUCTURE OF THIS GUIDE This guide is organized as follows: This chapter provides preliminary information to aid in using this manual, lists technology and user guides that may help the user set up and manage the module, and gives instructions on how to get help. Chapter 1, Introduction, provides an overview of the modules and their features. Chapter 2, Network Requirements, outlines the network requirements that must be met before installing the module.
Document Conventions DOCUMENT CONVENTIONS The guide uses the following conventions: Note symbol. Calls the reader’s attention to any item of information that may be of special importance. Tip symbol. Conveys helpful hints concerning procedures or actions. Caution symbol. Contains information essential to avoid damage to the equipment. Electrical Hazard Warning symbol. Warns against an action that could result in personal injury or death due to an electrical hazard. Warning symbol.
Getting Help GETTING HELP For additional support related to the module or this document, contact Enterasys Networks using one of the following methods: World Wide Web http://www.enterasys.com/ Phone (603) 332-9400 Internet mail support@enterasys.com FTP Login ftp://ftp.enterasys.com anonymous Password your email address To send comments or suggestions concerning this document, contact the Technical Writing Department via the following email address: TechWriting@enterasys.
1 Introduction This chapter introduces the 6H302-48 and 6H303-48 Fast Ethernet modules. Important Notice Depending on the firmware version used in the module, some features described in this document may not be supported. Refer to the Release Notes shipped with the module to determine which features are supported. There are restrictions on the version of firmware required for 6H302-48 modules with a serial number starting with 3655xxxxxx.
Figure 1-1 6H302-48 and 6H303-48 Modules FAST ENET FAST ENET 6H302-48 6H303-48 RESET RESET COM 1X CPU GROUP SELECT G R O U P GROUP GROUP COM COM Port System LED Group Select Switch 12X G R O U P System LED CPU GROUP SELECT GROUP GROUP Group Select Switch 1 1 11X 13X Port Status LEDs Group Select LEDs G R O U P 1X 24X G R O U P Port Status LEDs Group Select LEDs 2 2 13X Network Ports 1-48 23X 25X G R O U P Network Ports 1-48 36X G R O U P 3 3 25X 35X 37X G R O U
Connectivity 1.1 CONNECTIVITY The module connects to Ethernet networks or workstations through the front panel connectors. The ports support Unshielded Twisted Pair (UTP) cables with an impedance between 85 and 111 ohms at lengths up to 100 meters. The ports are IEEE 802.3 10BASE-T and 100BASE-TX compliant. 1.
Remote Monitoring (RMON) SmartTrunk, also referred to as SmartTrunking, is Enterasys Networks’ terminology for load balancing or load sharing. SmartTrunk provides the ability to take full advantage of the network’s redundant bandwidth. SmartTrunk divides network traffic across multiple ports in parallel to provide additional throughput. The SmartTrunk application can be used with any of Enterasys Networks’ switch modules (except ATM modules).
Traffic Rate Limiting The VLAN redirect function is similar to the port redirect function except that the frames received by the module are redirected to a designated destination port according to the VLAN classification of the frames received. Multiple VLANs can be directed to the same destination port. The VLAN redirect function is only supported when the module is operating as an 802.1Q switch. 1.
GARP Switch Operation The module supports Frame based 802.3x flow control. Frame based 802.3x flow control is supported on all Ethernet ports operating in the full-duplex mode. Flow control can be enabled or disabled on a port-by-port basis. Back pressure flow control is not supported on ports operating in the half-duplex mode. 1.
Management Installation in the SmartSwitch 6000 (6C105) Chassis The SmartSwitch 6000 chassis can be viewed as a single entity with a single IP address. Its systems management functions are distributed to all modules, including the 6H302-48 or 6H303-48. The chassis can be managed using a single IP address, or the modules can be managed separately by individual IP addresses.
Standards Compatibility 1.15 STANDARDS COMPATIBILITY The 6H302-48 and 6H303-48 modules are fully compliant with the IEEE 802.3, 802.3u, 802.3x, 802.1D, and 802.1Q standards. The modules provide IEEE 802.1D Spanning Tree Algorithm (STA) support to enhance the overall reliability of the network and protect against “loop” conditions.
2 Network Requirements Before installing the module, review the requirements and specifications referred to in this chapter concerning the following: • SmartTrunk (Section 2.1) • 10BASE-T Twisted Pair Network (Section 2.2) • 100BASE-T Twisted Pair Network (Section 2.3) The network installation must meet the requirements to ensure satisfactory performance of this equipment. Failure to do so will produce poor network performance.
100BASE-TX Network 2.3 100BASE-TX NETWORK The fixed front panel ports of the module provide a connection that supports Category 5 UTP cabling. The device at the other end of the twisted pair segment must meet IEEE 802.3u 100BASE-TX Fast Ethernet network requirements for the devices to operate at 100 Mbps. Refer to the Cabling Guide for details. NOTE: The fixed ports of the module support Category 5 UTP cabling with an impedance between 85 and 111 ohms for 100 Mbps operation.
3 Installation ELECTRICAL HAZARD: Only qualified personnel should install the module. NOTE: Read the Release Notes shipped with the module to check for any exceptions to the supported features and operation documented in this guide. This chapter provides the instructions to install the 6H302-48 or 6H303-48 module. A Phillips screwdriver is required to install options into the module. Follow the order of the sections listed below to correctly install the module. • Unpacking the Module (Section 3.
Unpacking the Module 3.1 UNPACKING THE MODULE Unpack the module as follows: 1. Open the box and remove the packing material protecting the module. 2. Verify the contents of the carton as listed in Table 3-1. Table 3-1 Contents of Module Carton Item Quantity One module, either the 6H302-48 or the 6H303-48 1 Antistatic Wrist Strap 1 Manual Accessory Kit 1 3. Remove the tape seal on the non-conductive bag to remove the module. 4.
Installing the Module into the Matrix E7 Chassis NOTE: The Matrix E7 (third generation modules) can provide backplane connectivity for the 6x1xx and 6x2xx series (first and second generation modules) in the Matrix E7 chassis. First and second generation boards installed in slots one through five in the Matrix E7 chassis cannot communicate with slots six and seven unless a third generation board (6x3xx) is installed in one of the first five slots.
Installing the Module into the Matrix E7 Chassis Figure 3-1 Installing a Module into the Matrix E7 Chassis Backplane Connectors Slot Number Plastic Locking Tab SERIES 1 2 3 4 5 6 E7 7 FAST ENET 6H302-48 RESET COM 1X CPU GROUP SELECT G R O U P GROUP GROUP 1 11X 13X G R O U P 2 23X 25X G R O U P 3 35X 37X G R O U P 4 47X AC ON AC ON ACON 1 0 POWER OK/ REDUNDANCY FAN STATUS 6C207-1 Plastic Locking Tab ACON 1 0 POWER OK/ REDUNDANCY FAN STATUS 6C207-1 3387_12 Metal Back-
Installing the Module into the 6C105 Chassis 5. Examine the module for damage. If any damage exists, DO NOT install the module. Immediately contact Enterasys Networks. Refer to “Getting Help,” in About This Guide. CAUTION: To prevent damaging the backplane connectors in the following step, take care that the module slides in straight and properly engages the backplane connectors. Ensure that the top plastic locking tab lines up with the desired slot number located on the front panel of the chassis.
Installing the Module into the 6C105 Chassis Figure 3-2 Installing a Module into the 6C105 Chassis Backplane Slot Number Connector Plastic Locking Tab 1 2 3 4 6 5 FAST ENET 6H302-48 7 RESET COM 1X CPU GROUP SELECT G R O U P GROUP GROUP 1 11X 13X G R O U P 2 23X 25X G R O U P 3 35X 37X G R O U P 4 47X Metal Back-Panel Circuit Card Card Guides Plastic Locking Tab 3387_02 3-6 Installation
Connecting to the Network 3.5 CONNECTING TO THE NETWORK This section provides the procedures for connecting unshielded twisted pair (UTP) segments from the network or other devices to the 6H302-48 (Section 3.5.1), or the 6H303-48 (Section 3.5.2). For details on how to get manuals, refer to the “Related Documents” section in About This Guide.
Connecting to the Network Figure 3-3 Connecting a Twisted Pair Segment to the 6H302-48 . FAST ENET 6H302-48 RESET COM 1X Group Select Button CPU GROUP SELECT G R O U P RX LED GROUP GROUP 1 TX LED 11X 3387_03 3. Verify that a link exists by checking that the port RX (Receive) LED is ON (flashing amber, blinking green, or solid green). If the RX LED is OFF and the TX (Transmit) LED is not blinking amber, perform the following steps until it is on: a.
Connecting to the Network Figure 3-4 Crossover Cable RJ45 Pinouts TO RJ45 Switch Port TO Other Device Port RX+ 1 1 RX+ NOTE: RX RX+/RX and TX+/TX must share a common color pair. TX+ 2 2 RX 3 3 TX+ TX 6 6 TX RJ45 to RJ45 Figure 3-5 3387_04 Straight-Through Cable RJ45 Pinouts TO RJ45 Switch Port NOTE: RX+/RX and TX+/TX must share a common color pair. TO Other Device Port RX+ 1 1 RX+ RX 2 2 RX TX+ 3 3 TX+ TX 6 6 TX RJ45 to RJ45 3387_05 e.
Connecting to the Network To connect a UTP segment to the 6H303-48, proceed as follows: 1. Ensure that the device connected to the other end of the segment is powered ON. 2. If using an RJ21 straight connector, plug it into the appropriate RJ21 port as shown in Figure 3-6. Figure 3-6 Connecting a Twisted Pair Segment to the 6H303-48 FAST ENET 6H303-48 RESET Screw Screw Hole COM 12X G R O U P CPU GROUP SELECT GROUP GROUP 1 1X Screw Link Status LEDs Screw Hole 24X 3387_06 3.
Completing the Installation b. Verify that the RJ21 connectors on the twisted pair segment have the proper pinouts and check the cable for continuity. c. Check that the twisted pair connection meets the specifications in the Cabling Guide. If a link is not established, contact Enterasys Networks. Refer to “Getting Help” in About This Guide for details. 5. Repeat steps 1 through 5, above, until all RJ21 connections are made. 3.
4 Troubleshooting This chapter provides information concerning the following: • Using LANVIEW (Section 4.1) • Troubleshooting Checklist (Section 4.2) • Using the RESET Button (Section 4.3) 4.1 USING LANVIEW The modules use a built-in visual diagnostic and status monitoring system called LANVIEW. The LANVIEW LEDs (Figure 4-1) allow quick observation of the network status to aid in diagnosing network problems. Viewing Receive and Transmit Activity Only one group of segments may be viewed at a time.
Using LANVIEW Figure 4-1 LANVIEW LEDs (both modules) FAST ENET 6H302-48 RESET COM 1X CPU GROUP SELECT G R O U P GROUP GROUP GROUP SELECT 1 GROUP Port 1, Group 1 LEDs 11X RX TX 13X 3387_07 Table 4-1 describes the LED indications and provides recommended actions as appropriate. NOTE: The terms flashing, blinking, and solid used in Table 4-1 indicate the following: Flashing indicates an LED is flashing randomly.
Using LANVIEW Table 4-1 LANVIEW LEDs LED Color State Recommended Action CPU Off Power off. Ensure chassis has adequate power. Red Blinking. Hardware failure has occurred. Contact Enterasys Networks for technical support. Solid. Resetting, normal power up reset. If the LED remains red for several minutes, contact Enterasys Networks for technical support. Blinking. Crippled. Contact Enterasys Networks for technical support. Solid. Testing.
Using LANVIEW Table 4-1 LANVIEW LEDs (Continued) LED Color State Recommended Action TX (Transmit) Off Port enabled, and no activity. 1. Ensure that the STA is enabled and that there is a valid link. 2. Contact Enterasys Networks for technical support. Should flash green every two seconds indicating BPDUs being sent if STA is enabled and there is a valid link. Green Flashing. Indicates activity. Rate indicates data rate. None. Amber Blinking. Port in standby. 1.
Troubleshooting Checklist 4.2 TROUBLESHOOTING CHECKLIST If the module is not working properly, refer to Table 4-2 for a checklist of problems, possible causes, and recommended actions to resolve the problem. Table 4-2 Troubleshooting Checklist Problem Possible Cause Recommended Action All LEDs are OFF. Loss of power. Ensure that the module was installed properly according to the installation instructions in Chapter 3, and that the host chassis is powered properly.
Troubleshooting Checklist Table 4-2 Troubleshooting Checklist (Continued) Problem Possible Cause Recommended Action Cannot contact the module through in-band management. IP address not assigned. Refer to the appropriate Local Management User’s Guide for the IP address assignment procedure. Port is disabled. Enable port. Refer to the appropriate Local Management User’s Guide for instructions to enable/disable ports. No link to device. 1.
Using the RESET Button 4.3 USING THE RESET BUTTON The RESET button shown in Figure 4-2 resets and re-initializes the module. CAUTION: Pressing the RESET button resets the device, and all current switching being performed by the module is halted. A network downtime of up to two minutes will result from this action for any devices connected to the module.
A Specifications This appendix provides operating specifications for the 6H302-48 and 6H303-48 modules. Enterasys Networks reserves the right to change the specifications at any time without notice. If not specified by module name, the statistics are the same for both modules. A.1 6H302-48 / 6H303-48 SPECIFICATIONS Table A-1 provides the processors and memory, physical properties, environmental module specifications, and I/O ports for the 6H302-48 and 6H303-48 modules.
6H302-48 / 6H303-48 Specifications Table A-1 6H302-48 / 6H303-48 Specifications (Continued) Item Specification Environmental Requirements Operating Temperature: 5°C to 40°C (41°F to 104°F) Storage Temperature: -30°C to 73°C (-22°F to 164°F) Operating Relative Humidity: 5% to 90% (non-condensing) Input/Output Ports 6H302-48: Ports 1 through 48: Fast Ethernet 10/100 Mbps (10BASE-T and 100BASE-TX compliant) with 48 RJ45 connectors.
COM Port Pinout Assignments A.2 COM PORT PINOUT ASSIGNMENTS The COM port is a serial communications port that supports Local Management or connection to a UPS. Table A-2 shows the COM port pin assignments.
B Mode Switch Bank Settings and Options This appendix covers the following items: • Required tools (Section B.1) • Locations, functions, and settings for the mode switches (Section B.2) • Upgrading the FLASH (Section B.3) B.1 REQUIRED TOOLS Use the following tools to perform the procedures provided in this appendix: • Antistatic wrist strap • Phillips screwdriver CAUTION: An antistatic wrist strap is required (provided with the module) to perform the procedures in this appendix.
Setting the Mode Switches B.2 SETTING THE MODE SWITCHES CAUTION: Read the appropriate sections to be fully aware of the consequences when changing switch settings. Only qualified personnel should change switch settings. Figure B-1 shows the location of the mode switches and the switch settings for normal operation. These switches are set at the factory and rarely need to be changed. Switch definitions and positions are as follows: • Switches 1 through 4 – For Enterasys Networks use only.
Setting the Mode Switches NOTE: After changing the position of Switch 6, DO NOT reapply power to the module until there is a station on the network acting as a BootP server, which contains the downloadable firmware image file. DO NOT attempt a Forced BootP unless a BootP server has been configured for the module. The BootP server references the location of a station acting as a Trivial File Transfer Protocol (TFTP) server containing the module image file.
FLASH Upgrade B.3 FLASH UPGRADE FLASH upgrade is available for the switch to expand from 8 to 16 MB. This section explains how to locate and add/replace the FLASH module. For details on getting help, refer to “Getting Help,” in About This Guide. B.3.1 Locating the FLASH Module Figure B-2 shows the location of the FLASH module.
FLASH Upgrade B.3.2 Installing the FLASH Module CAUTION: Observe all antistatic precautions when handling sensitive electronic equipment. To install a FLASH module, refer to Figure B-3 and proceed as follows: 1. With the FLASH module oriented as shown in Figure B-3, insert the FLASH module down between the connector. 2. Pivot the FLASH module downward so the connector clips align with the two side notches of the FLASH module and the connector clips lock the FLASH module into place.
Index Numerics D 100BASE-TX requirements 2-2 10BASE-T connection 3-7, 3-9 requirements 2-1 802.
M S Management use of 1-7 Mode Switch setting B-2 Module features 1-1 Module Installation 3-2 Safety requirements A-3 SecureFast Switching support 3-3, 3-5 SmartTrunk introduction to 1-3 Specifications A-1 Standards compatibility 1-8 Switching options introduction to 1-7 P Pinouts crossover 3-9 straight-through 3-9 Port redirect function introduction to 1-4 R Receive LEDs viewing of 4-1 Redirect functions port and VLAN introduction to 1-4 Regulatory Compliance A-3 Related manuals xii Remote Monitoring