Item Description Solution
1 When you run the MTE and import a MIB
with an object name longer than 30
characters, you receive the following
message, even when the object does not
import:
The MIB was successfully imported.
In a terminal window or on the Control
Panel, error messages display for MIB
objects with names consisting of 30 or
more characters that failed to import.
There are two workarounds:
1. The first is to identify each MIB
object with 30+ characters in its
name and shorten the name before
running the MTE.
2. The second (for attributes with
truncated group names) is to find
the attributes that are listed as no
group and manually assign the
truncated group name in the
Attribute View.
If the MTE was run from the Control
Panel, a list of MIB objects that did not
import display on the Control Panel.
If the MTE was run from the command
line, a list of MIB objects that did not
import display in that window.
This issue will be corrected in a future
release of SPECTRUM.