2 More information was needed when a
SpectroGRAPH received a “Permission
Denied” error when it tried to connect to
a SpectroSERVER. SecurityManager
(SM) reads the
.hostrc file after a
SpectroSERVER is started or the
.hostrc file is updated and tries to
resolve all the host entries in
.hostrc
by OS Service. Sometimes the OS
Service did not resolve the network
address for some hostnames listed in
.hostrc.
This was resolved by creating a new view
to display unresolved host names. The
VNM Control View -> Host Security
Information view displays lists of
resolved and unresolved hosts. Also, an
event and alarm (Event00010e01,
Prob00010e01) will be generated on the
VNM when there are unresolved host
names.
3 When the user, on NT 4.0, printed a
SpectroGRAPH topological view, the
sticky label icon was missing and not
printed on the device model. It seemed
that the problem was related to the
GnSNMPDev model type. If the user
modeled a device as a GnSNMPDev (or if
it was derived from GnSNMPDev) and
then selected “File”--”Print”--”Print
View”, the device was missing the sticky
label icon of the triangle and the words
“SNMP”. The sticky label icon appeared
fine in the GUI but was missing when the
view was printed. This was also seen on
Cisco devices; Cisco_2501/Cisco_2621,
4700, 4000, and Rtr_Cisco.
This was resolved by modifying the
repaint method.
4 SpectroGRAPH was experiencing
stability issues when a device DevTop
view was opened that contained a
Gen_IF_Port model that was displaying
performance statistics.
This was resolved by adjusting the code
that was not supporting 64-bit counters.
5 When running SpectroGRAPH on the
Windows platform, links between certain
models such a Rpt_Segment (Fanout)
model and a Pingable model, will display
green even though Live Pipes is not
enabled on the link. Also, in these
unusual cases, the link will stay green
even when the modeled link is down.
This was corrected by making
enhancements to Fault Management.
Corrected Issues: SpectroGRAPH
Item Problem Resolution