Specifications
SPECTRUM Software Release Notice (SSRN)
For SPECTRUM 6.6 with Service Pack 5 CD release
Page 41
Document 5156
6 A Cisco_Router management module
was losing some links to DLCI_Ports
when the model was reconfigured. This
problem occurred after migrating from
SPECTRUM 5.0rev1 and was caused by
the Frame Relay
Internal_IF_Type
attribute being set to 0 instead of 32.
This was resolved by creating a new
attribute that will check the value of an
interface's
Internal_If_Type upon
SpectroSERVER startup and write the
correct value if necessary. This check will
only occur on the first startup after
upgrade or install.
7 AutoDiscovery was not able to resolve
connections to the upstream and down
stream neighbors of Cisco devices that
used CDP.
This was resolved by adding support to
AutoDiscovery for reading CDP table
connection information.
8 AutoDiscovery was not resolving some
connections properly when the Layer 2
option, Source Address Table, was
selected.
This was resolved by enhancing
AutoDiscovery to include the default
route when determining if a device is
routing and removing the mutual hears
requirement when creating a connection
between ports.
9 Cisco Catalyst: The use of the variable
TIME in both the rcvBitsPerSecond
and
xmtBitsPerSecond
SpectroWATCH's was yielding inaccurate
results and was inconsistent with the
documentation.
This was resolved by modifying the
default values for both the
SWD_rcvBitsPerSecond
(0xc4063d)
and
SWD_xmtBitsPerSecond(0xc4063e)
attributes of the
CiscoAtmVclLnk
(0x210074)
model type, so that the
watch formula uses the
X_sysUpTime
variable instead of the
TIME variable.
10 Cisco Catalyst: When modeling a Cisco
Catalyst 3550 by IP, the device modeled
as a Rtr_Cisco MT.
This was resolved by entering the
SysOID of the device into the
SysOIDVerifyList within MTE in
order to recognize the device as a
SwCat35xx MT.
11 Fault Isolation: Proper Management
Neighbor modeling relies on which
devices are upstream/downstream
relative to the VNM. The Fault Isolation
GIB, which explains Management
Neighbor functionality, only tangentially
touched on the concept of proximity to
the VNM.
This was resolved by making the Fault
Isolation GIB more descriptive.
12 Forerunner: SpectroWatch calculations
for the attributes
SWD_rcvBitsPerSecond and
SWD_xmtBitsPerSecond were wrong.
This was resolved by changing the
atmLinkDerPt model type so that all
models deriving from it would inherit the
fixed calculations.
Corrected Issues: Management Modules
Item Problem Resolution