Specifications

Installing the Hardware
28 Enterasys Xpedition 2000 Getting Started Guide
To install a 1000BASE-SX or 1000BASE-LX gigabit expansion module:
1. Ensure that the XP-2000 is powered off.
2. If your XP-2000 is equipped for rack mounting, use the phillips-head screwdriver to
remove the mounting brackets from each side of the XP-2000.
3. Take off the XP-2000s top cover.
a. Use the phillips-head screwdriver to remove the four mounting screws (two on
each side of the router, front and back) that hold the top cover on the XP-2000.
Figure 10. Removing the XP-2000s cover
b. Slide the cover away from the front of the XP-2000 about 1/2, then lift it away
from the XP-2000.
4. Use the phillips-head screwdriver to remove the four mounting screws in the existing
face plate or cover plate corresponding to the expansion slot where you plan to install
the 1000BASE-SX or 1000BASE-LX gigabit expansion module. Be sure not to damage
or remove the conductive tape on the inside of the chassis, both above and below the
expansion slot opening.
Figure 11. Removing a face plate or cover plate (view from outside chassis)
5. From the inside of the chassis, line up the four holes in the expansion modules face
plate with the corresponding holes around the empty expansion slot in the chassis,
and use the phillips-head screwdriver to tighten the screws (from the front) on each
side of the expansion modules face plate to affix it to the chassis.
87654321 87654321
1
3
2
4
CONSOLE
10/100 MGMT
OK
ERR DIAG
HBT
RST
10/100BASE-TX 10/100BASE-TX
SYS
4
blank expansion module face plate