Hub/Switch V2H124-24P Installation Guide

3-1
Chapter 3: Installing the Switch
Selecting a Site
Matrix V-Series V2H124-24P units can be mounted in a standard 19-inch equipment
rack or on a flat surface. Be sure to follow the guidelines below when choosing a
location.
The site should:
- be at the center of all the devices you want to link and near a power outlet.
- be able to maintain its temperature within 0 to 50 °C (32 to 122 °F), and its
humidity within 5% to 95%, non-condensing
- provide adequate space (approximately two inches) on all sides for proper air
flow
- be accessible for installing, cabling, and maintaining the devices
- allow the status LEDs to be clearly visible
Make sure that twisted-pair cable is always routed away from power lines,
fluorescent lighting fixtures and other sources of electrical interference, such as
radios and transmitters.
Make sure that the unit is connected to a separate grounded power outlet that:
- provides 100 to 240 VAC, 50 to 60 Hz
- is within 2.44 m (8 feet) of each device
- is powered from an independent circuit breaker
As with any equipment, using a filter or surge suppressor is recommended.
Ethernet Cabling
To ensure proper operation when installing the switch into a network, make sure that
the current cables are suitable for 10BASE-T or 100BASE-TX operation. Check the
following criteria against the current installation of your network:
Cable type: Unshielded twisted pair (UTP) or shielded twisted pair (STP) cables
with RJ-45 connectors; Category 3 or better for 10BASE-T and Category 5 or
better for 100BASE-TX.
Protection from radio frequency interference emissions
Electrical surge suppression
Separation of electrical wires (switch related or other) and electromagnetic fields
from data based network wiring
Safe connections with no damaged cables, connectors or shields