Switch User Manual
clear system temperature
SecureStack C3 Configuration Guide 3-19
Parameters
Defaults
Syslogalertsaredisabledbydefault.
Trapalertsare disabledbydefault.
Overtempthresholdis100%bydefault.
Mode
Switchcommand,read‐write.
Usage
Ontheplatformsthatsupportthisfeature,temperaturesensorsarelocatedinseveraldifferent
locationswithinthedevice.Thresholdcalibrationshavebeencalculatedseparatelyforeach
platform.Thethermalovertempthresholdisthehigh‐watermarkthat,whenreached,triggersan
alerttowarnthesy stemadministratorthatthedeviceis
operatingathightemperatures.
Whenahightemperaturealertconditionoccurs,theCPULEDonthefrontpaneloftheswitch
willflashred.Inaddition,ifenabled,asyslogmessagewillbelog gedand/oranSNMPtrapwill
besent.
Thevaluessetwiththiscommandcanbeviewedwith
theshowsystemcommand.
Example
ThefollowingexampleenablessendingSNMPtrapsandsetstheovertempthresholdto60%.
C3(su)->set system temperature trap enable overtemp-threshold 60
clear system temperature
Usethiscommandtoresetsystemhightemperatureparameterstotheirdefaultvalues,onthe
platformsthatsupportthisfeature.
Syntax
clear system temperature
Parameters
None.
Defaults
None.
syslogenable|
disable
Enablesordisableslogginghightemperaturealertstothesystemlog
whenthesystemtransitionsintoanalarmstate.
trapenable|disable EnablesordisablessendinghightemperaturealertsbymeansofSNMP
trapswhenthesystemtransitionsintoanalarmstate.
overtemp‐threshold
value
Setsthethermal
thresholdasapercentageofthemaximumratedforthe
specificplatform.Valuecanrangefrom0to100%.