Switch User Manual

show igmpsnooping
SecureStack C3 Configuration Guide 13-3
show igmpsnooping
UsethiscommandtodisplayIGMPsnoopinginformation.
Syntax
show igmpsnooping
Parameters
None.
Defaults
None.
Mode
Switchcommand,readonly.
Usage
ConfiguredinformationisdisplayedwhetherornotIGMPsnoopingisenabled.Status
informationisdisplayedonlywhenthefunctionisenabled.ForinformationonenablingIGMPon
thesystem,refertosetigmpsnoopingadminmodeonpage 133.Forinformationonenabling
IGMPononeormoreports,referto
setigmpsnoopinginterfacemodeonpage 134.
Example
ThisexampleshowshowtodisplayIGMPsnoopinginformation:
C3(su)->show igmpsnooping
Admin Mode..................................... Enable
Group Membership Interval...................... 260
Max Response Time.............................. 100
Multicast Router Present Expiration Time....... 0
Interfaces Enabled for IGMP Snooping........... ge.1.1,ge.1.2,ge.1.3
Multicast Control Frame Count.................. 0
Data Frames Forwarded by the CPU............... 0
set igmpsnooping adminmode
UsethiscommandtoenableordisableIGMPonthesystem.
Syntax
set igmpsnooping adminmode {enable | disable}
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
enable|disable EnablesordisablesIGMPsnoopingonthesystem.