Switch User Manual
show spantree operedge
SecureStack C3 Configuration Guide 9-41
Parameters
Defaults
None.
Mode
Switchcommand,read‐write.
Example
Thisexampleshowshowtoresetge.1.11asanon‐edgeport:
C3(su)->clear spantree adminedge ge.1.11
show spantree operedge
UsethiscommandtodisplaytheSpanningTreeedgeportoperatingstatusforaport.
Syntax
show spantree operedge [port port-string]
Parameters
Defaults
Ifport‐stringisnotspecified,edgeportoperatingstatuswillbedisplayedforallSpanningTree
ports.
Mode
Switchcommand,read‐only.
Example
Thisexampleshowshowtodisplaytheedgeportstatusforge.2.7:
C3(rw)->show spantree operedge port ge.2.7
Port ge.2.7 has a Port Oper Edge of Edge-Port
port‐string Specifiesport(s)onwhichtoresetedgeportstatus.Foradetailed
descriptionofpossibleport‐stringvalues,referto“PortStringSyntaxUsed
intheCLI”onpage 7‐1.
portport‐string Displaysedgeportoperatingstatusforspecificport(s).