Switch User Manual
clear spantree spanguardtimeout
9-28 Spanning Tree Configuration
clear spantree spanguardtimeout
UsethiscommandtoresettheSpanningTreeSpanGuardtimeouttothedefaultvalueof300
seconds.
Syntax
clear spantree spanguardtimeout
Parameters
None.
Defaults
None.
Mode
Switchcommand,read‐write.
Example
ThisexampleshowshowtoresettheSpanGuardtimeoutto300seconds:
C3(rw)->clear spantree spanguardtimeout
show spantree spanguardlock
UsethiscommandtodisplaytheSpanGuardlockstatusofoneormoreports.
Syntax
show spantree spanguardlock [port-string]
Parameters
Defaults
Ifnoportstringisspecified,theS panGuardlockstatusforallportsisdisplayed.
Mode
Switchcommand,read‐only.
Example
ThisexampleshowshowtodisplaytheSpanGuardlock statusforge.1.1:
C3(su)->show spantree spanguardlock ge.1.1
Port ge.1.1 is Unlocked
port‐string (Optional)Specifiestheport(s)forwhichtoshowSpanGuardlockstatus.
Foradetaileddescriptionofpossibleport‐stringvalues,referto“PortString
SyntaxUsedintheCLI”onpage 7‐1.