Switch User Manual

clear snmp notifyfilter
SecureStack C3 Configuration Guide 8-35
Defaults
Ifnotspecified,maskisnotset.
Ifnotspecified,subtreewillbeincluded.
Ifstoragetypeisnotspecified,nonvolatile(permanent)willbeapplied.
Mode
Switchcommand,readwrite.
Usage
SeeAboutSNMPNotifyFiltersonpage 829formoreinformationaboutnotifyfilters.
Example
Thisexampleshowshowtocreatean SNMPnotifyfiltercalled“pilot1”withaMIBsubtreeIDof
1.3.6:
C3(su)->set snmp notifyfilter pilot1 subtree 1.3.6
clear snmp notifyfilter
UsethiscommandtodeleteanSNMPnotifyfilterconfiguration.
Syntax
clear snmp notifyfilter profile subtree oid-or-mibobject
Parameters
Defaults
None.
Mode
Switchcommand,readwrite.
Example
ThisexampleshowshowtodeletetheSNMPnotifyfilter“pilot1”:
C3(su)->clear snmp notifyfilter pilot1 subtree 1.3.6
included|
excluded
(Optional)Specifiesthatsubtreeisincludedorexcluded.
volatile|
nonvolatile
(Optional)Specifiesastoragetype.
profile SpecifiesanSNMPfilternotifynametodelete.
subtreeoidor
mibobject
SpecifiesaMIBsubtreeIDcontainingthefiltertobedeleted.