Switch User Manual

set linkflap downtime
SecureStack C3 Configuration Guide 7-31
Parameters
Defaults
None.
Mode
Switchmode,readwrite.
Example
Thisexampleshowshowtosetthelinkflapthresholdonportge.1.4to5.
C3(rw)->set linkflap threshold ge.1.4 5
set linkflap downtime
Usethiscommandtosetthetimeinterval(inseconds) oneormoreportswillbehelddownaftera
linkflapviolation.
Syntax
set linkflap downtime port-string downtime-value
Parameters
Defaults
None.
Mode
Switchmode,readwrite.
Example
Thisexampleshowshowtosetthelinkflapdowntimeonportge.1.4to5000seconds.
C3(rw)->set linkflap downtime ge.1.4 5000
clear linkflap down
Usethiscommandtotogglelinkflapdisabledportstooperational.
Syntax
clear linkflap down [port-string]
portstring Specifiestheport(s)onwhichtosetthelinkflapactiontriggercount.
thresholdvalue Specifiesthenumberoflinkdowntransitions necessarytotriggerthe
linkflapaction.Aminimumof1mustbeconfigured.
portstring Specifiestheport(s)onwhichtosetthelinkflapdowntime.
downtimevalue Specifiesadowntimeinseconds.Avalueof0willsetthedowntimeto
forever.