- Enterasys Gigabit and Fast Ethernet Switches Hardware Installation Guide
Table Of Contents
- Enterasys® SecureStack™ B2 Gigabit and Fast Ethernet Switches Hardware Installation Guide
- Notice
- Regulatory Compliance Information
- Federal Communications Commission (FCC) Notice
- Clase A. Aviso de ITE
- Klasse A ITE Anmerkung
- Seguridad del Producto
- Produktsicherheit
- Electromagnetic Compatibility (EMC)
- Compatibilidad Electromágnetica (EMC)
- Elektro- magnetische Kompatibilität ( EMC )
- VCCI Notice
- BSMI EMC Statement - Taiwan
- Safety Information Class 1 Laser Transceivers
- Enterasys Networks, Inc. Firmware License Agreement
- Regulatory Compliance Information
- Notice
- Contents
- About This Guide
- Introduction
- Network Requirements
- Hardware Installation
- Considerations Prior to Installation
- Required Tools
- Unpacking the Switch
- Installing Optional Mini-GBICs
- Installing the Switch on a Flat Surface
- Rack Mounting the Switch
- Connecting High-Speed Stacking Cables
- Configuring Switches in a Stack
- Connecting AC and RPS-SYS Power
- Connecting to Console Port for Local Management
- Connecting to the Network
- Completing the Installation
- Troubleshooting
- Specifications
- Index

Gigabit Ethernet Specifications
A-6 Specifications
MGBIC-LC09 Specifications (1000BASE-LX)
MGBIC-08 Specifications (1000BASE-ELX)
Table A-7 MGBIC-LC09 Optical Specifications
Item 62.5 µm MMF 50 µm MMF 10 µm SMF
Transmit Power (minimum) -11.5 dBm -11.5 dBm -9.5 dBm
Receive Sensitivity -20 dBm -20 dBm -20 dBm
Link Power Budget 8.5 dBm 8.5 dBm 10.5 dBm
Table A-8 MGBIC-LC09 Operating Range
Item
Modal Bandwidth @
1300 nm
Range
62.5 µm MMF 500 MHz/km 2-550 Meters
50 µm MMF 400 MHz/km 2-550 Meters
50 µm MMF 500 MHz/km 2-550 Meters
10 µm SMF N/A 2-10,000 Meters
Table A-9 MGBIC-08 Optical Specifications
Item
Transmit Power (minimum) -0 dBm, min. +2 dBm, typical +5 dBm, max.
Receive Sensitivity -24 dBm, min. -26 dBm, typical
Maximum Input Power -3 dBm
Link Power Budget
1
(Full Duplex Only)
1. The maximum drive distance (up to 70 km) depends on the quality of the installed single-mode
fiber-optic cable segment. Use the Link Power Budget to calculate the maximum cable length of the
attached segment. The Link Power Budget must not exceed those specified in this table. The
MGBIC-08 input power must not exceed -3 dBm. Otherwise, saturation could occur.
23 dB 28 dB, typical
Table A-10 MGBIC-08 Operating Range
Item 1550 nm Range
9 or 10 µm SMF N/A 70,000 Meters