Network Router User's Manual
Power Supply Requirements, Specifications, and Twist Lock Options
Matrix X16-C Chassis Installation Guide A-3
Table A-3 Module Power Specifications
Module
@ 110 Vac / 220 Vac
Power (Watts) Thermal Output (BTU/HR)
CM 97 Watts 331.1 BTU/HR
Fan tray 85 Watts 290.1 BTU/HR
X4-FM 30 Watts 102.4 BTU/HR
X8-FM 62 Watts 211.6 BTU/HR
X16-FM 98 Watts 334.5 BTU/HR
X-G32-00 155 Watts 520.0 BTU/HR
X-GT16-00 105 Watts 358.3 BTU/HR
X-M2-00 155 Watts 520.0 BTU/HR
X-T32-00 155 Watts 520.0 BTU/HR
Table A-4 Redundancy Configurations for AC Line 100–120 Vac
No. of Power Supplies
Maximum Redundant System Load
1
1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.
Redundancy Configuration
2 1160 Watts 1 + 1
3 2320 Watts N + 1
4 3480 Watts 1 + 1
4 3480 Watts N + 1
5 4640 Watts N + 1
6 5800 Watts 1 + 1
6 5800 Watts N + 1
Table A-5 Redundancy Configurations for AC Line 200–240 Vac
No. of Power Supplies
Maximum Redundant System Load
1
1. The sum of individual power draws for all installed fan trays, control and fabric modules, and IOMs.
Redundancy Configuration
2 1500 Watts 1 + 1
3 3000 Watts N + 1
4 3000 Watts 1 + 1
4 4500 Watts N + 1
5 6000 Watts N + 1
6 4500 Watts 1 + 1
6 6000 Watts N + 1