- Enterasys Ethernet Switches Reference Manual

show vlanauthorization
D-Series CLI Reference 15-45
Mode
Switchcommand,readwrite.
Example
ThisexampleshowhowtoclearVLANauthorizationforallportsonslots3,4,and5:
D2(rw)->clear vlanauthorization ge.3-5.*
show vlanauthorization
DisplaystheVLANauthenticationstatusandconfigurationinformationforthespecifiedports.
Syntax
show vlanauthorization [port-string]
Parameters
Defaults
Ifnoportstringisentered,thestatusforallportswillbedisplayed.
Mode
Switchcommand,readonly.
Example
ThiscommandshowshowtodisplayVLANauthorizationstatusforge.1.1:
G3(su)>showvlanauthorizationge.1.1
VlanAuthorization:‐enabled
port status administrative operational authenticated vlan id
egress egress mac address
------- -------- -------------- ----------- ----------------- -------
ge.1.1 enabled untagged
Table 1550providesanexplanationofcommandoutput.Fordetailsonenablingandassigning
protocolandegressattributes,refertosetvlanauthorizationonpage 1543andset
vlanauthorizationegressonpage 1544.
portstring (Optional)DisplaysVLANauthenticationstatusforthespecifiedports.If
noportstringisentered,then
theglobalstatusofthesettingisdisplayed.
Foradetaileddescriptionofpossibleportstringvalues,refertoPort
StringSyntaxUsedintheCLIonpage 4 1.
Table 15-50 show vlanauthorization Output Details
Output Field What It Displays...
port Port identification
status Port status as assigned by set vlanauthorization command
administrative
egress
Port status as assigned by the set vlanauthorization egress command
operational egress Port operational status of vlanauthorization egress.