Installation User's Guide SmartSwitch 2200 2H252-25R
Using LANVIEW
4-4 Troubleshooting
CPU Off Power off. Power up device.
Red Blinking. Hardware failure
has occurred.
Contact Enterasys Networks for
assistance.
Solid. Resetting, normal
power up reset.
If the LED remains Red for several
minutes, contact Enterasys
Networks for assistance.
Amber Blinking. Crippled. Contact Enterasys Networks for
assistance.
Solid. Testing. If the LED remains Amber for
several minutes, contact Enterasys
Networks for assistance.
Green Solid. Functional. None.
Amber
and
Green
Booting. Blinks amber and
green while booting.
None.
The following port RX and TX LED indications are only valid when the LED MODE switch is
in the RX-TX position.
RX
(Receive)
Off No link. None.
Green Solid. Port enabled, link, no
activity.
None.
Blinking. Port disabled,
link.
None.
Amber Flashing. Port enabled, link,
activity.
None.
Red Diagnostic failure. Contact Enterasys Networks for
assistance.
Table 4-1 LANVIEW LEDs (Continued)
LED Color State Recommended Action