- Enterasys Standalone Switch Installation Guide
Memory Locations and Replacement Procedures
B-8 Mode Switch Bank Settings and Optional Installations
3. PushtheconnectorarmsawayfromthememorymoduletoreleasetheDRAMSIMM
fromtheconnector,asshowninFigure B‐6.
Figure B-6 DRAM SIMM Connector Location
Installing the DRAM SIMM
Toinstallthememorymodule,refertoFigure B‐7andproceedasfollows:
1. PushtheconnectorarmsawayfromtheDRAMSIMMfarenoughtoinserttheDRAM
SIMMintotheconnectorcontacts.
2. InserttheDRAMSIMMstraightdownbetweentheconnectorcontactsfarenoughfor
thetabsontheconnectorarms
toalignwiththetwoDRAMSIMMalignmentnotches.
3. PushtheDRAMSIMMdownintotheconnectorcontacts.Thenrotatethetwo
connectorarmstowardtheDRAMSIMMtolockitintoplace.
Note: The ejector arms on this connector are not spring loaded, so they will remain in the
open position until manually closed.
1 Connector arms 2 DRAM SIMM 3 Connector contacts