Overview of Shutdown Procedure
4-6 Troubleshooting
Figure 4-2 RESET Button
Recommended Shutdown Procedure Using RESET Button
Beforeshuttingoffpowertoa2G 4072‐52,
pressortaponitsRESETbuttonforlessthan1second.
ItsCPULEDchangesfromsolidgreentoblinkingbetweengreenandamber,indi cating
thatthe2G4072‐52isshuttingdown.Attheendoftheshutdownroutine,theCPULED
changestoa67%/33%sequenceofamber/off,respectively,indicatingthesystemisina
haltstate.Atthistimeit
issafetorestartthe2G4072‐52.
WhenyouinitiateacontrolledshutdownwiththeRESETbutton,youhave60seconds
fromthetimetheCPUstartsflashingamber/offuntilthedeviceautomaticallyrestarts.
Last Resort Shutdown Procedure Using RESET Button
Toreseta2G4072‐52withoutitperforminganorderlyshutdownroutine,
pressandholdthe RESETbuttonforapproximately6seconds.
RESET
CONSOLE
CPU
PWR
GROUP
SELECT
GROUP 3
GROUP 2
GROUP 1
Reset button
Caution: This method of shutting down a Enterasys Matrix N SA 2G4072-52 is not
recommended except as a last resort, because all processes currently running on the
module will be interrupted resulting in loss of frames.
Precaución: No se recomienda utilizar este método para apagar los módulos Enterasys
Matrix N SA 2G4072-52. Recurra a él sólo como último recurso, puesto que interrumpe
todos los procesos del módulo en funcionamiento, lo que podría resultar pérdidas de
frames.