User`s guide

6—Editing Algorithms
ENSONIQ DP/Pro Reference Manual 27
Parameter Name Ref Value Min Max Attributes
L-V2 Regen +0% -200% +200% B
L-V2 Regen Fc 1.000kHz 1Hz 20.000kHz H, L
L-V2 Regen BW Full 0.01oct Full
L-V2 Level +0.0dB -99.0dB +0.0dB
L-V2 Pan Center Full <L Full >R
L-V3 Pitch +0cents -9600cents +9600cents B
L-V3 Splice Time 10ms 0ms 200ms
L-V3 Delay 0ms 0ms 200ms
L-V3 Regen +0% -200% +200% B
L-V3 Regen Fc 1.000kHz 1Hz 20.000kHz H, L
L-V3 Regen BW Full 0.01oct Full
L-V3 Level +0.0dB -99.0dB +0.0dB
L-V3 Pan Center Full <L Full >R
R-V1 Pitch +0cents -9600cents +9600cents B
R-V1 Splice Time 10ms 0ms 200ms
R-V1 Delay 0ms 0ms 200ms
R-V1 Regen +0% -200% +200% B
R-V1 Regen Fc 1.000kHz 1Hz 20.000kHz H, L
R-V1 Regen BW Full 0.01oct Full
R-V1 Level +0.0dB -99.0dB +0.0dB
R-V1 Pan Center Full <L Full >R
R-V2 Pitch +0cents -9600cents +9600cents B
R-V2 Splice Time 10ms 0ms 200ms
R-V2 Delay 0ms 0ms 200ms
R-V2 Regen +0% -200% +200% B
R-V2 Regen Fc 1.000kHz 1Hz 20.000kHz H, L
R-V2 Regen BW Full 0.01oct Full
R-V2 Level +0.0dB -99.0dB +0.0dB
R-V2 Pan Center Full <L Full >R
R-V3 Pitch +0cents -9600cents +9600cents B
R-V3 Splice Time 10ms 0ms 200ms
R-V3 Delay 0ms 0ms 200ms
R-V3 Regen +0% -200% +200% B
R-V3 Regen Fc 1.000kHz 1Hz 20.000kHz H, L
R-V3 Regen BW Full 0.01oct Full
R-V3 Level +0.0dB -99.0dB +0.0dB
R-V3 Pan Center Full <L Full >R
B=parameter has bi-polar range G=maximum gain limited by Set Max Gain System/MIDI parameter
H=high-frequency limit determined by system sample rate M=parameter has supplemental metered display
L=lowest frequency limited by Set Min Freq System/MIDI parameter T=parameter can be synchronized to system clock or MIDI clocks