User`s guide

6—Editing Algorithms
ENSONIQ DP/Pro Reference Manual 17
17 Loop Recorder
Right
Left
Output
Left
Right
Input
Loop
Recorder
Level
Detector
Mix
Mix
Play, Stop, Rec, etc.
Description: Records and plays samples. Playback speed can be decreased to near zero or can be
increased to up to 1600 times the original rate. Samples can be played both forwards and backwards
(hence positive and negative speeds), and the end of a sample can be spliced to the beginning with an
adjustable fade-in/out time. Audio-triggering modes allow sample playback to be keyed by an audio
source and allow recording to begin automatically when the source level exceeds a threshold.
I/O Characteristics: Mono-in, mono-out.
Parameter Name Ref Value Min Max Attributes
Mix Full Dry Full Wet Full Wet B
Function Pla [Stop]Rec [Play]Stop Rec Play Sto [Rec]
Play Mode Once Once Loop
Sample Start 0ms 0ms 2730ms
Sample End 2730ms 0ms 2730ms
Playback Speed +0% -1600% +1600% B
Fade Time 0ms 0ms 2730ms
Play Trigger Manual Manual Audio
Play Threshold -20.0dB -99.0dB +0.0dB
Play Hysteresis +89.0dB +0.0dB +99.0dB
Record Trigger Manual Manual Audio
Record Threshold -20.0dB -99.0dB +0.0dB
B=parameter has bi-polar range G=maximum gain limited by Set Max Gain System/MIDI parameter
H=high-frequency limit determined by system sample rate M=parameter has supplemental metered display
L=lowest frequency limited by Set Min Freq System/MIDI parameter T=parameter can be synchronized to system clock or MIDI clocks