User`s guide

10—Effect Modulation
10 ENSONIQ DP/Pro Reference Manual
Rate Value
(synchronized)
45 135
-180
-90
90
-45
0
-135
When Note Phase=0, the LFO will start
at its center point at each occurrence of
the selected value, and move up first, then down
When Note Phase=180, the LFO will start
at its center point at each occurrence of
the selected value, and move down, then up
Note: When a mod LFO’s Rate is set to an unsynchronized value, this parameter is
unavailable.
Mod A/B Parameter 65: (LFO 1) Note Phase
Mod A/B Parameter 68: (LFO 2) Note Phase
LFO 1 Shape=Sine Rate=1/2
Note Phase=45
i
Values: -180; -135; -90; -45; 0; 45; 90; 135; 180
What these Parameters Do:
The (LFO 1) Note Phase and (LFO 2) Phase determine the location of the LFO wave at each occurrence
of the selected synchronized Rate value. Positive values cause the wave to start in an upward
direction; negative values start the wave in a downward direction.