Configure the triggering parameters.
Parameter Description
Schedule
Define a period during which the detection is active.
For details, see "Setting Motion Detection Period" section in "5.10.4.1
Configuring Motion Detection Settings."
Alarm-out Port
Click Setting to display setting interface.
General Alarm: Enable general alarm and select the alarm output
port.
Ext. Alarm: Connect the alarm box to the Device and then enable
it.
Wireless Siren: Connect the wireless gateway to the Device and
then enable it. For details, see "5.12 IoT Function."
When an alarm event occurs, the system links the peripheral alarm
devices connected to the selected output port.
Post-Alarm
Set a length of time for the Device to delay turning off alarm after the
external alarm is cancelled. The value ranges from 0 seconds to 300
seconds. If you enter 0, there will be no delay.
Show Message
Select the Show Message check box to enable a pop-up alarm
message in your local host PC.
Report Alarm
Select the Report Alarm check box to enable the system to upload the
alarm signal to the network (including alarm center) when an alarm
event occurs.
Not all models support this function.
The corresponding parameters i
n the alarm center should be
configured. For details, see "5.15.1.12 Configuring Alarm Center
Settings."